The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Selective Detection of 2,4,6‐Trinitrophenol and Cu2+ Ions Based on a Fluorescent Cadmium–Pamoate Metal–Organic Framework
Abstract
A luminescent cadmium–pamoate metal–organic framework, [Cd 2(PAM)2(dpe)2(H 2 O)2]⋅0.5(dpe) (1), has been synthesized under hydrothermal conditions by using π‐electron‐rich ligands 4,4′‐methylenebis(3‐hydroxy‐2‐naphthalenecarboxylic acid) (H 2 PAM) and 1,2‐di(4‐pyridyl)ethylene (dpe). Its structure is composed of both mononuclear and dinuclear Cd II building units, which are linked by the PAM and dpe ligands, resulting in a (4,8)‐connected 3D framework. The π‐conjugated dpe guests are located in a 1D channel of 1. The strong emission of 1 could be quenched efficiently by trace amounts of 2,4,6‐trinitrophenol (TNP), even in the presence of other competing analogues such as 4‐nitrophenol, 2,6‐dinitrotoluene, 2,4‐dinitrotoluene, nitrobenzene, 1,3‐dinitrobenzene, hydroquinone, dimethylbenzene, and bromobenzene. The high sensitivity and selectivity of the fluorescence response of 1 to TNP shows that this framework could be used as an excellent sensor for identifying and quantifying TNP. In the same manner, 1 also exhibits superior selectivity and sensitivity towards Cu 2+ compared with other metal ions such as Zn 2+, Mn 2+, Mg 2+, K+, Na+, Ni 2+, Co 2+, and Ca 2+. This is the first MOF that can serve as a dual functional fluorescent sensor for selectively detecting trace amounts of TNP and Cu 2+.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vertebrate ancient opsin and melanopsin: divergent irradiance detectors
Davies, W. L., Hankins, M. W., & Foster, R. G. (2010) · Photochemical & Photobiological Sciences · doi:10.1039/c0pp00203h · Cited by 100
Cited by
Sensing organic analytes by metal–organic frameworks: a new way of considering the topic
Hu, M.-L., Razavi, S. A. A., Piroozzadeh, M., & Morsali, A. (2020) · Inorganic Chemistry Frontiers · doi:10.1039/c9qi01617a · Cited by 295
Liu, W., Huang, X., Xu, C., Chen, C., Yang, L., Dou, W., Chen, W., Yang, H., & Liu, W. (2016) · Chemistry – A European Journal · doi:10.1002/chem.201603607 · Cited by 278
Metal ion detection using luminescent-MOFs: Principles, strategies and roadmap
Razavi, S. A. A., & Morsali, A. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213299 · Cited by 262
Hu, Y., Ding, M., Liu, X.-Q., Sun, L.-B., & Jiang, H.-L. (2016) · Chemical Communications · doi:10.1039/c6cc01597b · Cited by 261
Sanda, S., Parshamoni, S., Biswas, S., & Konar, S. (2015) · Chemical Communications · doi:10.1039/c4cc10442k · Cited by 255
Metadata
- Authors
- Ye, J., Zhao, L., Bogale, R. F., Gao, Y., Wang, X., Qian, X., Guo, S., Zhao, J., & Ning, G.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2014-11-27
- Volume
- 21
- Issue
- 5
- Pages
- 2029-2037
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2148606619
- Cited by
- 221
- References
- 1
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Selective Detection of 2,4,6‐Trinitrophenol and Cu2+ Ions Based on a Fluorescent Cadmium–Pamoate Metal–Organic Framework. https://app.cochat.ai/papers/10.1002/chem.201405267
- The paper
- Ye, J., Zhao, L., Bogale, R. F., Gao, Y., Wang, X., Qian, X., Guo, S., Zhao, J., & Ning, G. (2015). Highly Selective Detection of 2,4,6‐Trinitrophenol and Cu2+ Ions Based on a Fluorescent Cadmium–Pamoate Metal–Organic Framework. Chemistry – A European Journal. https://doi.org/10.1002/chem.201405267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.