Mass transfer in external‐loop airlift bioreactors using static mixers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The influence of static mixers on the overall gas‐liquid volumetric mass transfer coefficient (KL a L) was examined in an external‐loop type airlift bioreactor (approximately 15 L volume, 1.8 m static liquid height, A r/A d = 0.444). The study was conducted with aqueous salt solution (0.15 kmol ṁ m−3 NaCl) and with pseudoplastic solutions of carboxymethyl cellulose (0.2 − 0.6 wt./vol. % (g/100 mL) CMC). Over a broad range of power law parameters K (10−3 − 10 Pa ṁ s n) and n (0.5 − 1.0), the presence of static mixers in the riser was found to enhance the K L a L relative to mixer‐free mode of operation. The extent of increase in K L a L depended on the fluid “thickness”, K: the higher the K, the greater the K L a L intensification due to static mixers. For otherwise identical conditions, the presence of static mixers improved K L a L by 30‐500%, depending on the fluid. The boost in K L a L was associated with increased gas holdup and gas‐liquid interfacial area, which arose due to bubble breakup accomplished by the static mixing elements. Potential advantages of static mixers in upgrading the performance of oxygen‐limited fermentations were pointed out.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gas Absorption by Newtonian and Non-Newtonian Liquids in a Bubble Column
Nakanoh, M., & Yoshida, F. (1980) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260073a033 · Cited by 217
Cited by
Chisti, Y. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.02.001 · Cited by 9,524
Self-citationPhotobioreactors: Light regime, mass transfer, and scaleup
Molina Grima, E., Fernández, F. G. A., Garcı́a Camacho, F., & Chisti, Y. (1999) · Journal of Biotechnology · doi:10.1016/s0168-1656(99)00078-4 · Cited by 603
Static Mixers in the Process Industries—A Review
Thakur, R. K., Vial, C., Nigam, K. D. P., Nauman, E. B., & Djelveh, G. (2003) · Chemical Engineering Research and Design · doi:10.1205/026387603322302968 · Cited by 597
Ugwu, J. O. (2002) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-002-0940-9 · Cited by 180
“The use of static mixers in bioreactors has been reported (Hsu et al. 1975; Lin et al. 1976; Wang and Fan 1978; Stejskal and Potucek 1985; Chisti et al. 1990; Zhou et al. 1993).”
Paladino, O., Neviani, M., Ciancio, D., & De Francesco, M. (2024) · Biomass Conversion and Biorefinery · doi:10.1007/s13399-022-03634-3 · Cited by 7
“Moreover, this kind of control action is complex if the flue gas is used to stir the photobioreactor, as in tubular bubble reactors, or even more in airlift reactors where flue gas or a mixture of air/flue gas sparged from the bottom of the riser is used to assure the operation [20, 21].”
Metadata
- Authors
- Chisti, Y., Kasper, M., & Moo‐Young, M.
- Venue
- The Canadian Journal of Chemical Engineering
- Publisher
- Wiley
- Published
- 1990-02
- Volume
- 68
- Issue
- 1
- Pages
- 45-50
- ISSN
- 0008-4034 (ISSN-L)
- 1939-019X
- OpenAlex
- W2061230708
- Cited by
- 83
- References
- 1
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass transfer in external‐loop airlift bioreactors using static mixers. https://app.cochat.ai/papers/10.1002/cjce.5450680106
- The paper
- Chisti, Y., Kasper, M., & Moo‐Young, M. (1990). Mass transfer in external‐loop airlift bioreactors using static mixers. The Canadian Journal of Chemical Engineering. https://doi.org/10.1002/cjce.5450680106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.