CoChat

Comparing outcomes after transcatheter aortic valve replacement in patients with stenotic bicuspid and tricuspid aortic valve: A systematic review and meta‐analysis

Open access
Kanjanahattakij, Napatt, Horn, Benjamin, Vutthikraivit, Wasawat, Biso, Sylvia Marie, Ziccardi, Mary Rodriguez, Lu, Marvin Louis Roy, Rattanawong, Pattara · 2018 · Clinical Cardiology
Cited by 37

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Transcatheter aortic valve replacement (TAVR) has become an alternative treatment to surgery in patients with severe aortic stenosis. However, patients with bicuspid aortic stenosis (BAV) are usually excluded from major TAVR studies. The aim of this study is to reexamine current evidence of TAVR in patients with severe aortic stenosis and BAV compared with tricuspid aortic valve (TAV). Hypothesis: There might be differences in outcomes post TAVR between patients with BAV comparing to TAV. Method: Databases were systematically searched for relevant articles featuring cohort studies that included patients with BAV and TAV who underwent TAVR studies, of which reported outcomes of interest included mortality and complications in both groups. Pooled effect size was calculated with a random‐effect model and weighted for the inverse of variance, to compare outcomes post‐TAVR between BAV and TAV. Results: Nine studies were included in the meta‐analysis. There was no difference in 30‐day mortality rate in patients with BAV compared with TAV (OR: 1.27, 95% CI: 0.84–1.93, I2 = 0). Patients with BAV were more likely to have a moderate to severe paravalvular leak (9 studies; OR: 1.42, 95% CI: 1.08–1.87, I2 = 0) and conversion to surgery (5 studies; OR: 5.48, 95% CI: 1.74–17.27, I2 = 0), and less likely to have device success compared with patients with TAV (5 studies; OR: 0.57, 95% CI: 0.40–0.81, I2 = 0%). Conclusions: There was no difference in mortality post‐TAVR in patients with BAV compared with TAV. Further randomized studies should be done in newer‐generation prostheses to assess this association.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/clc.22992

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Kanjanahattakij, N., Horn, B., Vutthikraivit, W., Biso, S. M., Ziccardi, M. R., Lu, M. L. R., & Rattanawong, P.
Venue
Clinical Cardiology
Publisher
Wiley
Published
2018-07
Volume
41
Issue
7
Pages
896-902
ISSN
  • 0160-9289 (ISSN-L)
  • 1932-8737
OpenAlex
W2807780188
Cited by
37
References
3
FWCI
1.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.