Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow

Klibanov, A. L., Rychak, J. J., Yang, W. C., Alikhani, S., Li, B., Acton, S., Lindner, J. R., Ley, K., Kaul, S. · 2006 · Contrast Media & Molecular Imaging

Abstract

Targeted ultrasound contrast materials (gas-filled microbubbles carrying ligands to endothelial selectins or integrins) have been investigated as potential molecular imaging agents. Such microbubbles normally exhibit good targeting capability at the slower flow conditions. However, in the conditions of vigorous flow, binding may be limited. Here, we describe a microbubble capable of efficient binding to targets both in slow and fast flow (exceeding 4 dyne/cm(2) wall shear stress) using a clustered polymeric form of the fast-binding selectin ligand sialyl Lewis(X). Microbubbles were prepared from decafluorobutane gas and stabilized with a monolayer of phosphatidylcholine, PEG stearate and biotin-PEG-lipid. Biotinylated PSLe(x) (sialyl Lewis(X) polyacrylamide) or biotinylated anti-P-selectin antibody (RB40.34) was attached to microbubbles via a streptavidin bridge. In a parallel plate flow chamber targeted adhesion model, PSLe(x) bubbles demonstrated specific adhesion, retention and slow rolling on P-selectin-coated plates. Efficiency of firm targeted adhesion to a P-selectin surface (140 molecules/microm(2)) was comparable for antibody-carrying bubbles and PSLe(x)-targeted bubbles at 0.68 dyne/cm(2) shear stress. At fast flow (4.45 dyne/cm(2)), PSLe(x)-targeted bubbles maintained their ability to bind, while antibody-mediated targeting dropped more than 20-fold. At lower surface density of P-selectin (7 molecules/microm(2)), targeting via PSLe(x) was more efficient than via antibody under all the flow conditions tested. Negative control casein-coated plates did not retain bubbles in the range of flow conditions studied. To confirm echogenicity, targeted PSLe(x)-bubbles were visualized on P-selectin-coated polystyrene plates by ultrasound imaging with a clinical scanner operated in pulse inversion mode; control plates lacking targeted bubbles did not show significant acoustic backscatter. In vivo, in a murine model of inflammation in the femoral vein setting, targeting efficacy of intravenously administered PSLe(x)-microbubbles was comparable with targeting mediated by anti-P-selectin antibody, and significantly exceeded the accumulation of non-targeted control bubbles. In the inflamed femoral artery setting, PSLe(x)-mediated microbubble targeting was superior to antibody-mediated targeting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cmmi.113

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Klibanov, A. L., Rychak, J. J., Yang, W. C., Alikhani, S., Li, B., Acton, S., Lindner, J. R., Ley, K., & Kaul, S.
Venue
Contrast Media & Molecular Imaging
Publisher
Wiley
Published
2006
Volume
1
Issue
6
Pages
259-266
ISSN
  • 1555-4309 (ISSN-L)
  • 1555-4317
OpenAlex
W2104657690
Cited by
166
References
1
FWCI
7.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow. https://app.cochat.ai/papers/10.1002/cmmi.113
The paper
Klibanov, A. L., Rychak, J. J., Yang, W. C., Alikhani, S., Li, B., Acton, S., Lindner, J. R., Ley, K., & Kaul, S. (2006). Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow. Contrast Media & Molecular Imaging. https://doi.org/10.1002/cmmi.113

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.