The DOI matches its Crossref record.
Endoscopic ultrasound-guided fine-needle aspiration in 179 cases: The M. D. Anderson Cancer Center experience
Open accessAbstract
BACKGROUND: Recently, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has emerged as a diagnostic adjunct for small pancreatic lesions and abdominal and mediastinal lymph node diseases. DESIGN: During a 21-month period, we performed 179 EUS-FNAs in 166 consecutive patients; these data are the subject of this study. An average of 2.6 needle passes were obtained and aspiration was performed most commonly in the pancreas (162 cases, 91%). The FNA smears were reviewed using six diagnostic categories (negative for malignancy/nondiagnostic [NND], atypia, suspicious for malignancy, benign tumor/cyst, neuroendocrine neoplasm [NEN], and carcinoma). The review diagnosis was correlated with the histologic diagnosis made on resection or surgical biopsy specimens in 70 cases. Up to 17 months of clinical follow-up were sought for the cases with a negative or inconclusive FNA diagnosis and no diagnostic tissue confirmation (81 cases). RESULTS: The review FNA diagnoses were as follows: NND (49 cases), atypia (17 cases), suspicious for malignancy (12 cases), benign tumor/cyst excluding NEN (10 cases), NEN (6 cases), carcinoma (85 cases). Follow-up methods included resection (49 cases), surgical biopsy (21 cases), repeat FNA or brushing cytology (28 cases), and clinical follow-up only (81 cases). Of the 49 NND cases, 23 (47%) had positive follow-up results (i.e., false-negative diagnosis) that were confirmed by tissue diagnosis (resection/surgical biopsy in 11 cases [48%] and repeat FNA/brushing in 12 cases [52%]). These included pancreatic/ampullary adenocarcinoma in 20 cases, esophageal squamous carcinoma in 1 case, and NEN in 2 cases. Follow-up also revealed carcinoma in all 12 suspicious cases and 13 pancreatic adenocarcinomas and 1 microcystic adenoma in 14 of the 17 atypical cases. Overall, repeat computed tomography (CT)-guided FNA samples yielded a definite diagnosis in four atypical and seven NND cases, whereas EUS-FNA results provided a definite diagnosis in three cases in which CT-guided FNA failed and in two cases in which ampullary biopsy failed. No false-positive cases were identified. The false-negative rate due to inadequate sampling was 13.2%. Sensitivity (including cases with inadequate cellularity and nondiagnostic aspirates) was 81.7% and specificity was 100%. None of the factors evaluated (lesion characteristics, aspiration site, and tumor type) significantly influenced diagnostic results. CONCLUSION: EUS-FNA is a valuable diagnostic and staging tool with high specificity and sensitivity. Negative or nondiagnostic cases on EUS-FNA require further diagnostic work for a definitive diagnosis when clinical or radiographic findings do not correlate with the FNA results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging of Neuroendocrine Tumors
Rufini, V., Calcagni, M. L., & Baum, R. P. (2006) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2006.03.007 · Cited by 376
Imaging of Neuroendocrine Tumors
Heller, M. T., & Shah, A. B. (2011) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2011.02.011 · Cited by 329
Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis
LeBlanc, J. K., Ciaccia, D., Al-Assi, M. T., McGrath, K., Imperiale, T., Tao, L.-C., Vallery, S., DeWitt, J., Sherman, S., & Collins, E. (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)02863-3 · Cited by 282
Endoscopic ultrasound in the localisation of pancreatic islet cell tumours.
McLean, A. M., & Fairclough, P. D. (2005) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2004.11.012 · Cited by 163
Metadata
- Authors
- Shin, H. J. C., Lahoti, S., & Sneige, N.
- Venue
- Cancer
- Publisher
- Wiley
- Published
- 2002-05-23
- Volume
- 96
- Issue
- 3
- Pages
- 174-180
- ISSN
- 0008-543X (ISSN-L)
- OpenAlex
- W2029008305
- Cited by
- 172
- References
- 0
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endoscopic ultrasound-guided fine-needle aspiration in 179 cases: The M. D. Anderson Cancer Center experience. https://app.cochat.ai/papers/10.1002/cncr.10614
- The paper
- Shin, H. J. C., Lahoti, S., & Sneige, N. (2002). Endoscopic ultrasound-guided fine-needle aspiration in 179 cases: The M. D. Anderson Cancer Center experience. Cancer. https://doi.org/10.1002/cncr.10614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.