Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Volume and process of care in high‐risk cancer surgery

Open access
Birkmeyer, John D., Sun, Yating, Goldfaden, Aaron, Birkmeyer, Nancy J.O., Stukel, Therese A. · 2006 · Cancer

Abstract

BACKGROUND: Although relations between procedure volume and operative mortality are well established for high‐risk cancer operations, differences in clinical practice between high‐volume and low‐volume centers are not well understood. The current study was conducted to examine relations between hospital volume, process of care, and operative mortality in cancer surgery. METHODS: Using the Medicare claims database (2000‐2002), we identified all patients undergoing major resections for lung, esophageal, gastric, liver, or pancreatic cancer (n = 71,558). Preoperative, intraoperative, and postoperative processes of care potentially related to operative mortality were identified from inpatient, outpatient, and physician claims files using appropriate International Classification of Diseases – Clinical Modification (ICD‐9) and Current Procedural Terminology (CPT) codes. We then assessed variation in the use of each process according to hospital volume, adjusting for patient characteristics and procedure type. Study Participants were US Medicare patients. The main outcome measure was specific processes of care. RESULTS: Relative to those at low‐volume centers (lowest 20th by volume), patients at high‐volume hospitals (highest 20th) were significantly more likely to undergo stress tests (odds ratio [OR]: 1.51, 95% confidence interval [CI]: 1.21‐1.87), but not other preoperative imaging tests. They were more likely to see medical or radiation oncologists (OR: 1.37, 95% CI: 1.16‐1.62), but not other specialists, preoperatively. Although blood transfusions and use of epidural pain management did not vary significantly by volume, patients at high‐volume hospitals had significantly longer operations and were more likely to receive perioperative invasive monitoring (OR: 2.56, 95% CI: 1.82‐3.60). Differences in measurable processes of care did not explain volume‐related differences in operative mortality to any significant degree. CONCLUSIONS: Although high‐volume and low‐volume hospitals differ with regard to many aspects of perioperative care, mechanisms underlying volume–outcome relations in high‐risk cancer surgery remain to be identified. Cancer 2006. © 2006 American Cancer Society.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cncr.21888

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 221

Metadata

Authors
Birkmeyer, J. D., Sun, Y., Goldfaden, A., Birkmeyer, N. J. O., & Stukel, T. A.
Venue
Cancer
Publisher
Wiley
Published
2006-05-18
Volume
106
Issue
11
Pages
2476-2481
ISSN
  • 0008-543X (ISSN-L)
  • 1097-0142
OpenAlex
W1970009268
Cited by
221
References
1
FWCI
42.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Volume and process of care in high‐risk cancer surgery. https://app.cochat.ai/papers/10.1002/cncr.21888
The paper
Birkmeyer, J. D., Sun, Y., Goldfaden, A., Birkmeyer, N. J. O., & Stukel, T. A. (2006). Volume and process of care in high‐risk cancer surgery. Cancer. https://doi.org/10.1002/cncr.21888

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.