Standardization, Calibration, and Control in Flow Cytometry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Because flow cytometers are designed to measure particle characteristics, particles are the most common materials used to calibrate, control, and standardize the instruments. Definitions and cautions are provided for common terms to alert the reader to critical distinctions in meaning. This unit presents extensive background on particle types and cautions and describes practical aspects of methods to standardize and calibrate instruments. Procedures are provided to characterize performance in terms of optical alignment, fluorescence and light scatter resolution, and sensitivity. Finally, suggestions follow for analyzing particles used for calibration. © 2017 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of Cell-Size from Pulse Shape in Flow Cytofluorometry
Sharpless, T. K., & Melamed, M. R. (1976) · Journal of Histochemistry & Cytochemistry · doi:10.1177/24.1.1254921 · Cited by 80
Pulse Width for Particle Sizing
Hoffman, R. A. (2009) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0123s50 · Cited by 36
Self-citationAn automated protocol for performance benchmarking a widefield fluorescence microscope
Halter, M., Bier, E., DeRose, P. C., Cooksey, G. A., Choquette, S. J., Plant, A. L., & Elliott, J. T. (2014) · Cytometry Part A · doi:10.1002/cyto.a.22519 · Cited by 28
Cited by
Welsh, J. A., Van Der Pol, E., Arkesteijn, G. J. A., Bremer, M., Brisson, A., Coumans, F., Dignat‐George, F., Duggan, E., Ghiran, I., Giebel, B., et al. (2020) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2020.1713526 · Cited by 481
Human bone marrow assessment by single-cell RNA sequencing, mass cytometry, and flow cytometry
Oetjen, K. A., Lindblad, K. E., Goswami, M., Gui, G., Dagur, P. K., Lai, C., Dillon, L. W., McCoy, J. P., & Hourigan, C. S. (2018) · JCI Insight · doi:10.1172/jci.insight.124928 · Cited by 272
A compendium of single extracellular vesicle flow cytometry
Welsh, J. A., Arkesteijn, G. J. A., Bremer, M., Cimorelli, M., Dignat‐George, F., Giebel, B., Görgens, A., Hendrix, A., Kuiper, M., Lacroix, R., et al. (2023) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12299 · Cited by 251
Review of flow cytometry as a tool for cell and gene therapy
Lazarski, C. A., & Hanley, P. J. (2024) · Cytotherapy · doi:10.1016/j.jcyt.2023.10.005 · Cited by 25
Lucas, F., Gil‐Pulido, J., LaMacchia, J., Preffer, F., Wallace, P. K., & Lopez, P. (2020) · Cytometry Part A · doi:10.1002/cyto.a.23940 · Cited by 10
Metadata
- Authors
- Wang, L., & Hoffman, R. A.
- Venue
- Current Protocols in Cytometry
- Publisher
- Wiley
- Published
- 2017-01
- Volume
- 79
- Issue
- 1
- ISSN
- 1934-9297 (ISSN-L)
- 1934-9300
- OpenAlex
- W4251108015
- Cited by
- 90
- References
- 3
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.