NICS‐XY‐Scan Predictions of Local, Semi‐Global, and Global Ring Currents in Annulated Pentalene and s‐Indacene Cores Compared to First‐Principles Current Density Maps
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The magnetic response of a set of 20 molecules, their dications and their dianions has been studied by the NICS‐XY method, and the results have been compared with first principles current density maps. The molecules have been built from pentalene and s‐indacene by single and double annulation of cyclobutadiene, benzene and benzocyclobutadiene in an alternate fashion on both sides of the molecules. The prediction of tropicities obtained by the NICS‐XY method are overall consistent with the current density maps. A literal code, developed to give a compact description of the tropicities of currents flowing around rings and bonds cut by the scan trajectory shows that, in most cases, the NICS‐XY method leads to an exact match with the current density analyses. Mismatches are generally due to small circulations out of the scan trajectory, and they do not correspond to misinterpretations of the overall tropicities. The dataset provides several cases where the prediction of the overall antiaromatic/aromatic response by the 4 n/4 n+2 count of π electrons fails.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steiner, E., & Fowler, P. W. (2001) · The Journal of Physical Chemistry A · doi:10.1021/jp011955m · Cited by 459
Bohmann, J. A., Weinhold, F., & Farrar, T. C. (1997) · The Journal of Chemical Physics · doi:10.1063/1.474464 · Cited by 306
Four- and two-electron rules for diatropic and paratropic ring currents in monocyclic π systems
Steiner, E., & Fowler, P. W. (2001) · Chemical Communications · doi:10.1039/b104847n · Cited by 292
Cited by
Aromaticity Reversal Induced by Vibrations in Cyclo[16]carbon
Rončević, I., Leslie, F. J., Rossmannek, M., Tavernelli, I., Gross, L., & Anderson, H. L. (2023) · Journal of the American Chemical Society · doi:10.1021/jacs.3c10207 · Cited by 35
Rimmele, M., Nogala, W., Seif-Eddine, M., Roessler, M. M., Heeney, M., Plasser, F., & Glöcklhofer, F. (2021) · Organic Chemistry Frontiers · doi:10.1039/d1qo00901j · Cited by 20
Aromaticity and Antiaromaticity: How to Define Them
Baranac-Stojanović, M. (2025) · Chemistry · doi:10.3390/chemistry7040127 · Cited by 14
Orbital contributions to the magnetic shielding of cyclo[2 n ]carbons ( n = 3–12)
Baranac-Stojanović, M. (2025) · Physical Chemistry Chemical Physics · doi:10.1039/d5cp00032g · Cited by 3
Metadata
- Authors
- Stanger, A., Monaco, G., & Zanasi, R.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2019-12-12
- Volume
- 21
- Issue
- 1
- Pages
- 65-82
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W2981343960
- Cited by
- 42
- References
- 3
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NICS‐XY‐Scan Predictions of Local, Semi‐Global, and Global Ring Currents in Annulated Pentalene and s‐Indacene Cores Compared to First‐Principles Current Density Maps. https://app.cochat.ai/papers/10.1002/cphc.201900952
- The paper
- Stanger, A., Monaco, G., & Zanasi, R. (2020). NICS‐XY‐Scan Predictions of Local, Semi‐Global, and Global Ring Currents in Annulated Pentalene and s‐Indacene Cores Compared to First‐Principles Current Density Maps. ChemPhysChem. https://doi.org/10.1002/cphc.201900952
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.