Beyond Beer's Law: Why the Index of Refraction Depends (Almost) Linearly on Concentration
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Beer's empiric law states that absorbance is linearly proportional to the concentration. Based on electromagnetic theory, an approximately linear dependence can only be confirmed for comparably weak oscillators. For stronger oscillators the proportionality constant, the molar attenuation coefficient, is modulated by the inverse index of refraction, which is itself a function of concentration. For comparably weak oscillators, the index of refraction function depends, like absorbance, linearly on concentration. For stronger oscillators, this linearity is lost, except at wavenumbers considerably lower than the oscillator position. In these transparency regions, linearity between the change of the index of refraction and concentration is preserved to a high degree. This can be shown with help of the Kramers–Kronig relations which connect the integrated absorbance to the index of refraction change at lower wavenumbers than the corresponding band. This finding builds the foundation not only for refractive index sensing, but also for new interferometric approaches in IR spectroscopy, which allow measuring the complex index of refraction function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beer's Law‐Why Integrated Absorbance Depends Linearly on Concentration
Mayerhöfer, T. G., Pipa, A. V., & Popp, J. (2019) · ChemPhysChem · doi:10.1002/cphc.201900787 · Cited by 110
Self-citationQuantitative Evaluation of Infrared Absorbance Spectra – Lorentz Profile versus Lorentz Oscillator
Mayerhöfer, T. G., & Popp, J. (2019) · ChemPhysChem · doi:10.1002/cphc.201800961 · Cited by 43
Self-citationDeviations from Beer's law on the microscale – nonadditivity of absorption cross sections
Mayerhöfer, T. G., Höfer, S., & Popp, J. (2019) · Physical Chemistry Chemical Physics · doi:10.1039/c9cp01987a · Cited by 35
Self-citation
Cited by
The Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
Self-citationBeyond Beer's Law: Revisiting the Lorentz‐Lorenz Equation
Mayerhöfer, T. G., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000301 · Cited by 61
Self-citationBeyond Beer's Law: Spectral Mixing Rules
Mayerhöfer, T. G., & Popp, J. (2020) · Applied Spectroscopy · doi:10.1177/0003702820942273 · Cited by 32
Self-citation
Metadata
- Authors
- Mayerhöfer, T. G., Dabrowska, A., Schwaighofer, A., Lendl, B., & Popp, J.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2020-03-11
- Volume
- 21
- Issue
- 8
- Pages
- 707-711
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W3007575412
- Cited by
- 62
- References
- 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.