The DOI matches its Crossref record.
Mouse and Rat Anesthesia and Analgesia
Open accessAbstract
Anesthesia and analgesia play pivotal roles in ethically and humanely using animal models in research, especially concerning mice and rats. These rodent species, extensively utilized in scientific investigations due to their genetic resemblance to humans, serve as invaluable tools for studying diseases and testing treatments. Proper anesthesia and analgesia not only prioritize animal welfare but also heighten experimental validity by minimizing stress‐induced physiological responses. Recent years have seen remarkable advancements in anesthesia for mice and rats. The focus has shifted away from the ‘one size fits all’ toward tailoring anesthesia protocols, considering factors like age, strain, and the nature of the experimental procedure. The use of inhalation agents such as isoflurane and sevoflurane is often preferred due to their rapid induction and recovery characteristics, allowing precise control over anesthesia depth. However, refinements in injectable anesthetic agents also provide researchers the flexibility to select suitable agents based on study requirements. Additionally, progress in analgesic techniques has led to effective pain management strategies for these rodents. Common analgesics such as nonsteroidal anti‐inflammatory drugs (NSAIDs), opioids, and local anesthetics are administered to alleviate pain and discomfort. However, standard practice also involves continuous monitoring of animals' behavior and physiological parameters, ensuring timely adjustments in analgesic regimens for optimal pain relief without compromising experimental outcomes. By integrating tailored anesthesia and analgesia protocols into the experimental design, researchers uphold high animal welfare standards while obtaining reliable scientific data. This contributes significantly to advancing medical knowledge and therapeutic interventions with reproducible results. Published 2024. This article is a U.S. Government work and is in the public domain in the USA. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1 : Injectable anesthesia for mouse and rat Basic Protocol 2 : Inhalant anesthesia using isoflurane for mouse and rat Basic Protocol 3 : Analgesia for mice and rats
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“meaning that these cohorts were in a state of post-anesthesia recovery and NOT anesthetizied for 92% (11 of 12 hours) of the experiments10.”
From A curious concept of CNS clearance (2025) · cites this paper as [10]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“PENTO induces an anesthetic plane for 10–300 minutes, KET-XYL for 30–45 minutes, and DEX (with KET) for 20–30 minutes”
From A curious concept of CNS clearance (2025) · cites this paper as [10]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 36
- 10.1136/vr.140.21.553 · DOI
- Adelsperger A. R., 2016, Use of a low‐flow digital anesthesia system for mice and rats, Journal of Visualized Experiments: JoVE
- 10.1007/BF01950180 · DOI
- 10.1213/00000539‐198903000‐00035 · DOI
- Anderson L. C., 2015, Laboratory animal medicine
- 10.1056/NEJM199110173251610 · DOI
- 10.1016/j.cvex.2021.08.013 · DOI
- 10.1186/1746‐6148‐9‐48 · DOI
- 10.1002/0471142301.nsa04bs42 · DOI
- 10.1002/jat.727 · DOI
- 10.1002/0471142301.nsa04fs33 · DOI
- 10.1038/s41598‐021‐90331‐2 · DOI
- Dyson M., 2023, American College of Laboratory Animal Medicine Series
- Flecknell P. A., 1996, Laboratory animal anesthesia
- 10.1111/j.1467‐2995.1990.tb00381.x · DOI
- 10.30802/AALAS‐CM‐19‐000048 · DOI
- Gehling A. M., 2018, Evaluation of volume of intramuscular injection into the caudal thigh muscles of female and male BALB/c Mice (Mus musculus), Journal of the American Association for Laboratory Animal Science: JAALAS, 57, 35
- 10.1258/002367792780740620 · DOI
- 10.1016/j.jss.2018.03.016 · DOI
- 10.1213/00000539‐198311000‐00005 · DOI
- 10.30802/AALAS‐JAALAS‐22‐000061 · DOI
- 10.1016/S0014‐4835(89)80045‐4 · DOI
- 10.1016/S0007‐1935(05)80036‐3 · DOI
- 10.1258/002367798780600025 · DOI
- 10.1258/002367786780865142 · DOI
- 10.1258/002367786780865089 · DOI
- 10.1258/002367786780808802 · DOI
- Mitzner W., 2001, In vivo measurement of lung volumes in mice, Physiol, Genomics, 4, 215
- 10.4103/0976‐0105.177703 · DOI · Paper page
- 10.1093/ilar/ilab016 · DOI
- 10.1016/j.brainresbull.2020.10.011 · DOI
- 10.1258/002367793781082377 · DOI
- Thurmon J. C., 1996, Lumb and Jones’ veterinary anesthesia, 183
- Turner P. V., 2005, Susceptibility of rats to corneal lesions after injectable anesthesia, Comparative Medicine, 55, 175
- Vender J. R., 1995, Oxygen saturation monitoring in experimental surgery: A comparison of pulse oximetry and arterial blood gas measurement, Laboratory Animal Science, 45, 211
- 10.1053/gast.2000.16510 · DOI
Cited by
Sorted by citations
A curious concept of CNS clearance
Plá, V., Kroesbergen, E., Deng, S., Giannetto, M. J., Hablitz, L. M., Newbold, E., Ladrón-de-Guevara, A., Esmail, T., Gomolka, R. S., Mori, Y., et al. (2025) · Nature Neuroscience · doi:10.1038/s41593-025-01897-3 · Cited by 15
Metadata
- Authors
- Oh, S. S., & Narver, H. L.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Narver, Heather L.
- ORCID
- Oh, Sang Su
- Venue
- Current Protocols
- Publisher
- Wiley
- Published
- 2024-02
- Volume
- 4
- Issue
- 2
- Pages
- e995-e995
- ISSN
- 2691-1299 (ISSN-L)
- PMC
- PMC10914332
- OpenAlex
- W4392170701
- Cited by
- 139
- References
- 0
- Citations by year
- 2026: 64 · 2025: 62 · 2024: 13
- FWCI
- 73.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Current Protocols (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (Z99 NS999999)
- National Institute of Neurological Disorders and Stroke (ZIGNS009444)
- Topics
- Health Sciences › Veterinary › Small Animals › Veterinary Pharmacology and Anesthesia
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
- Keywords
- anesthesia, analgesia, mice, rats, isoflurane, sevoflurane, inhalational anesthesia, injectable anesthetics, nonsteroidal anti-inflammatory drugs, opioids, local anesthetics, animal welfare, depth of anesthesia monitoring
- MeSH terms
- Analgesia, Analgesics, Anesthesia, Anesthetics, Local, Animals, Humans, Isoflurane, Pain, Mice, Rats, Pain Management
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review