The DOI matches its Crossref record.
Automated electron diffraction tomography – a new tool for nano crystal structure analysis
Abstract
Automated electron Diffraction Tomography (ADT) comprises an upcoming method for “ab intio” structure analysis of nano crystals. ADT allows fine sampling of the reciprocal space by sequential collection of electron diffraction patterns while tilting a nano crystal in fixed tilt steps around an arbitrary axis. Electron diffraction is collected in nano diffraction mode (NED) with a semi‐parallel beam with a diameter down to 50 nm. For crystal tracking micro‐probe STEM imaging is used. Full automation of the acquisition procedure allowed optimisation of the electron dose distribution and therefore analysis of highly beam sensitive samples. Cell parameters, space group and reflection intensities can be determined directly within a reconstructed 3d diffraction volume using a dedicated software package (ADT3D). Intensity data sets extracted from such a volume usually show a high coverage and significantly reduced dynamical effects due to “off‐zone” acquisition. The use of this data for “ab initio” structure solution by direct methods implemented in standard programs for X‐ray crystallography is demonstrated. (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
3D Electron Diffraction: The Nanocrystallography Revolution
Gemmi, M., Mugnaioli, E., Gorelik, T. E., Kolb, U., Palatinus, L., Boullay, P., Hovmöller, S., & Abrahams, J. P. (2019) · ACS Central Science · doi:10.1021/acscentsci.9b00394 · Cited by 530
Self-citationControl of zeolite framework flexibility and pore topology for separation of ethane and ethylene
Bereciartua, P. J., Cantín, Á., Corma, A., Jordá, J. L., Palomino, M., Rey, F., Valencia, S., Corcoran, E. W., Kortunov, P., Ravikovitch, P. I., et al. (2017) · Science · doi:10.1126/science.aao0092 · Cited by 460
The CryoEM Method MicroED as a Powerful Tool for Small Molecule Structure Determination
Jones, C. G., Martynowycz, M. W., Hattne, J., Fulton, T. J., Stoltz, B. M., Rodriguez, J. A., Nelson, H. M., & Gonen, T. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00760 · Cited by 446
Wan, W., Sun, J., Su, J., Hovmöller, S., & Zou, X. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813027714 · Cited by 343
Rapid Structure Determination of Microcrystalline Molecular Compounds Using Electron Diffraction
Gruene, T., Wennmacher, J. T. C., Zaubitzer, C., Holstein, J. J., Heidler, J., Fecteau‐Lefebvre, A., De Carlo, S., Müller, E., Goldie, K. N., Regeni, I., et al. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201811318 · Cited by 274
Metadata
- Authors
- Kolb, U., Mugnaioli, E., & Gorelik, T. E.
- Venue
- Crystal Research and Technology
- Publisher
- Wiley
- Published
- 2011-04
- Volume
- 46
- Issue
- 6
- Pages
- 542-554
- ISSN
- 0232-1300 (ISSN-L)
- 1521-4079
- OpenAlex
- W2090654284
- Cited by
- 201
- References
- 0
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated electron diffraction tomography – a new tool for nano crystal structure analysis. https://app.cochat.ai/papers/10.1002/crat.201100036
- The paper
- Kolb, U., Mugnaioli, E., & Gorelik, T. E. (2011). Automated electron diffraction tomography – a new tool for nano crystal structure analysis. Crystal Research and Technology. https://doi.org/10.1002/crat.201100036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.