Cited by 28Microfluidic and Capillary Electrophoresis ApplicationsAtmospheric-Pressure Plasma ApplicationsAnalytical chemistry methods development

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Determination of nitrites and nitrates in plasma‐activated deionized water by microchip capillary electrophoresis

Abstract

In this work, we present the application of a fast and sensitive microanalytical method, microchip capillary electrophoresis (MCE), for the determination of NO 2− and NO 3− ions in deionized water treated by atmospheric pressure plasma jet (APPJ). The MCE technique consisted of an online combination of isotachophoresis with zone electrophoresis, both performed on the microchip. The argon plasma has been characterized by optical emission spectroscopy (OES) and Fourier transform infrared spectroscopy (FTIR). OES confirmed the presence of argon excited species (Ar I) emission (4p → 4s) lines, N 2 emission bands (second positive system C 3 Π u → B 3 Π g), and OH band (A 2∑+ → X 2 Π Δ v = 0), as well as the presence of NO and excited NO 2. The presence of NO 2 molecules was also confirmed by FTIR absorption spectroscopy. The performance of the developed MCE method was evaluated for linearity, limit of detection, limit of quantitation, precision, and accuracy, and the concentration of NO 2− and NO 3− in the water as a function of the water treatment time was monitored.

Overview

Integrity signals

Registry

Crossref · 10.1002/ctpp.202000014

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 44 references

Research works printed but not linked: 7

  1. Judée F., 2016, Plasma Med., 6, 15823
  2. Kanazawa S., 2012, Int. J. Plasma Environ. Sci. Technol., 6, 166
  3. 10.1021/ac990198 · DOI
  4. Baezzat M. R., 2011, Quim. Nova, 34, 607
  5. Narayana B., 2009, Eurasian J. Anal. Chem., 4, 204
  6. Morabit Y., 2019, Plasma Process Polym., e1900217
  7. International Conference on Harmonization (ICH) Validation of analytical procedures: text and methodology Q2(R1) Geneva2005.

Cited by

Sorted by citations

See all 28

Metadata

Authors
Moravský, L., Troška, P., Klas, M., Masár, M., & Matejčík, Š.
Affiliations
Comenius University Bratislava (SK)
Corresponding author
Moravský, Ladislav
Venue
Contributions to Plasma Physics
Publisher
Wiley
Published
2020-02-29
Volume
60
Issue
7
ISSN
  • 0863-1042 (ISSN-L)
  • 1521-3986
OpenAlex
W3008605684
Cited by
28
References
44
Citations by year
2026: 4 · 2025: 8 · 2024: 2 · 2023: 4 · 2022: 5 · 2021: 5
FWCI
1.10
Type
journal article
Language
en
Open access
closed
Locations
Contributions to Plasma Physics (publishedVersion)
Funders
  • Agentúra na Podporu Výskumu a Vývoja (APVV‐0259‐12, APVV‐17‐0318)
  • Vedecká Grantová Agentúra MŠVVaŠ SR a SAV (VEGA 1/0733/17, VEGA 1/0787/18)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atmospheric-Pressure Plasma Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
Keywords
nitrite determination, nitrate determination, atmospheric pressure plasma jet, plasma-activated water, microchip electrophoresis, isotachophoresis, zone electrophoresis, argon plasma, plasma emission spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of nitrites and nitrates in plasma‐activated deionized water by microchip capillary electrophoresis. https://app.cochat.ai/papers/10.1002/ctpp.202000014
The paper
Moravský, L., Troška, P., Klas, M., Masár, M., & Matejčík, Š. (2020). Determination of nitrites and nitrates in plasma‐activated deionized water by microchip capillary electrophoresis. Contributions to Plasma Physics. https://doi.org/10.1002/ctpp.202000014