The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A pragmatic approach to the analysis of DNA histograms with a definable G1 peak
Abstract
A method for DNA histogram analysis is described that depends only on the simple assumption that the data are normally distributed and a requirement that a G1 peak is present. A probability density function was derived from the assumption that extracted the S‐phase component from the whole histogram. The model was tested with simulated data, and good agreement between predicted and known proportions in G1, S, and G1+M was found. Good agreement was also found between duplicates of experimentally derived data. Some systematic errors are present in the analysis of certain types of histograms. However, these result in small errors when compared with biological and experimental variation and are less than the average of algorithms in current use. The program required only two queued requests, those of the start and the end channels over which the analysis is to be performed. The algorithms perform rapidly on a micro‐computer with only 28K addressable memory. Only two failures occurred in over 350 analyses and the method can be used for drug‐ and radiation‐perturbed populations as well as with unperturbed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MATHEMATICAL ANALYSIS OF DNA DISTRIBUTIONS DERIVED FROM FLOW MICROFLUOROMETRY
Dean, P. N., & Jett, J. H. (1974) · The Journal of Cell Biology · doi:10.1083/jcb.60.2.523 · Cited by 791
CELL LOSS FROM EXPERIMENTAL TUMOURS
Steel, G. G. (1968) · Cell Proliferation · doi:10.1111/j.1365-2184.1968.tb00318.x · Cited by 285
A rapid single step staining technique for DNA analysis by flow microfluorimetry.
Taylor, I. W. (1980) · Journal of Histochemistry & Cytochemistry · doi:10.1177/28.9.6157714 · Cited by 284
Beck, H. (1978) · Cell Proliferation · doi:10.1111/j.1365-2184.1978.tb00882.x · Cited by 25
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationSchafer, K. A. (1998) · Veterinary Pathology · doi:10.1177/030098589803500601 · Cited by 604
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Self-citationHoffman, A. E., Zheng, T., Yi, C., Leaderer, D., Weidhaas, J., Slack, F., Zhang, Y., Paranjape, T., & Zhu, Y. (2009) · Cancer Research · doi:10.1158/0008-5472.can-09-0236 · Cited by 345
Wilson, G. M., Fielding, A. B., Simon, G. C., Yu, X., Andrews, P. D., Hames, R. S., Frey, A. M., Peden, A. A., Gould, G. W., & Prekeris, R. (2005) · Molecular Biology of the Cell · doi:10.1091/mbc.e04-10-0927 · Cited by 308
Metadata
- Authors
- Watson, J. V., Chambers, S. H., & Smith, P. J.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 8
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2144737712
- Cited by
- 256
- References
- 4
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A pragmatic approach to the analysis of DNA histograms with a definable G1 peak. https://app.cochat.ai/papers/10.1002/cyto.990080101
- The paper
- Watson, J. V., Chambers, S. H., & Smith, P. J. (1987). A pragmatic approach to the analysis of DNA histograms with a definable G1 peak. Cytometry. https://doi.org/10.1002/cyto.990080101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.