The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Modified histogram subtraction technique for analysis of flow cytometry data
Open accessAbstract
Analysis of flow cytometry histogram data by the subjective selection of an integration window can be a tedious and time‐consuming task and is often inaccurate. A new method for automated calculation of the percent positive from immunofluorescence histograms is presented. This new method is a modification of the currently used method of channel‐by‐channel histogram subtraction. Its accuracy is compared to that of the channel‐by‐channel histogram subtraction method and to another currently used automated method, which selects an integration window by finding the channels that contain the most fluorescent 2% of a control histogram. The new histogram subtraction method is objective, easy to use, and is more accurate than other currently used automated analysis methods. PASCAL source code is given for each method of analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strong, D. M., Ortaldo, J. R., Pandolfi, F., et al. (1982) · Journal of Clinical Immunology · doi:10.1007/bf00915224 · Cited by 48
Cited by
Armstrong, J. S., Rajasekaran, M., Chamulitrat, W., Gatti, P., Hellstrom, W. J., & Sikka, S. C. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(98)00275-5 · Cited by 339
Park, S. L., Zaid, A., Hor, J. L., Christo, S. N., Prier, J. E., Davies, B., Alexandre, Y. O., Gregory, J. L., Russell, T. A., Gebhardt, T., et al. (2018) · Nature Immunology · doi:10.1038/s41590-017-0027-5 · Cited by 326
Sperm DNA fragmentation: threshold value in male fertility
Sergerie, M., Laforest, G., Bujan, L., Bissonnette, F., & Bleau, G. (2005) · Human Reproduction · doi:10.1093/humrep/dei231 · Cited by 309
SAILER, B. L., JOST, L. K., & EVENSON, D. P. (1995) · Journal of Andrology · doi:10.1002/j.1939-4640.1995.tb01735.x · Cited by 254
Quah, B. J. C., & Parish, C. R. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.02.012 · Cited by 162
Metadata
- Authors
- Overton, W. R.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1988-11
- Volume
- 9
- Issue
- 6
- Pages
- 619-626
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2118160968
- Cited by
- 254
- References
- 1
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modified histogram subtraction technique for analysis of flow cytometry data. https://app.cochat.ai/papers/10.1002/cyto.990090617
- The paper
- Overton, W. R. (1988). Modified histogram subtraction technique for analysis of flow cytometry data. Cytometry. https://doi.org/10.1002/cyto.990090617
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.