The DOI matches its Crossref record.
High gradient magnetic cell separation with MACS
Abstract
A flexible, fast and simple magnetic cell sorting system for separation of large numbers of cells according to specific cell surface markers was developed and tested. Cells stained sequentially with biotinylated antibodies, fluorochrome‐conjugated avidin, and superparamagnetic biotinylated‐microparticles (about 100 nm diameter) are separated on high gradient magnetic (HGM) columns. Unlabelled cells pass through the column, while labelled cells are retained. The retained cells can be easily eluted. More than 10 9 cells can be processed in about 15 min. Enrichment rates of more than 100‐fold and depletion rates of several 1,000‐fold can be achieved. The simultaneous tagging of cells with fluorochromes and very small, invisible magnetic beads makes this system an ideal complement to flow cytometry. Light scatter and fluorescent parameters of the cells are not changed by the bound particles. Magnetically separated cells can be analysed by fluorescence microscopy or flow cytometry or sorted by fluorescence‐activated cell sorting without further treatment. Magnetic tagging and separation does not affect cell viability and proliferation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monocyte chemoattractant protein 1 acts as a T-lymphocyte chemoattractant.
Carr, M. W., Roth, S. J., Luther, E., Rose, S. S., & Springer, T. A. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.9.3652 · Cited by 1,198
Legler, D. F., Loetscher, M., Roos, R. S., Clark-Lewis, I., Baggiolini, M., & Moser, B. (1998) · The Journal of Experimental Medicine · doi:10.1084/jem.187.4.655 · Cited by 837
Defrance, T., Vanbervliet, B., Brière, F., Durand, I., Rousset, F., & Banchereau, J. (1992) · The Journal of experimental medicine · doi:10.1084/jem.175.3.671 · Cited by 638
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Self-citation
Metadata
- Authors
- Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1990-01
- Volume
- 11
- Issue
- 2
- Pages
- 231-238
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2017985531
- Cited by
- 1,681
- References
- 0
- FWCI
- 28.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High gradient magnetic cell separation with MACS. https://app.cochat.ai/papers/10.1002/cyto.990110203
- The paper
- Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990). High gradient magnetic cell separation with MACS. Cytometry. https://doi.org/10.1002/cyto.990110203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.