The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Comparison of autofocus methods for automated microscopy
Open accessAbstract
Traditional autofocus methods were designed for microscopes driven by single processor computers. As computers are developed that exploit massive parallelism when acquiring and analyzing images, parallel cellular logic techniques became available to focus automatically. This paper introduces the reader to both cellular logic techniques for autofocus and a new spectral moment autofocus measure. It then compares these methods with more traditional autofocus methods. It is shown that traditional methods based on measurements of image power‐give the best results when tested on one set of real images and two sets of synthetic images. The next best methods are the cellular logic and spectral moment techniques, while the worst are those based on the image probability density function or histogram.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Image analysis and mathematical morphology
(1982) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(82)90078-8 · Cited by 8,151
Image Analysis and Mathematical Morphology.
Diggle, P. J., & Serra, J. (1983) · Biometrics · doi:10.2307/2531038 · Cited by 3,894
A Mathematical Theory of Communications
Shannon, C. E. (1948) · Cited by 2,080
A comparison of different focus functions for use in autofocus algorithms
Groen, F. C. A., Young, I. T., & Ligthart, G. (1985) · Cytometry · doi:10.1002/cyto.990060202 · Cited by 446
An automated microscope for cytologic research a preliminary evaluation.
Brenner, J. F., Dew, B. S., Horton, J., King, T., Neurath, P. W., & Selles, W. D. (1976) · Journal of Histochemistry & Cytochemistry · doi:10.1177/24.1.1254907 · Cited by 257
Automatic Analysis of Blood Cells
Ingram, M., & Preston, K. (1970) · Scientific American · doi:10.1038/scientificamerican1170-72 · Cited by 105
Self-citation
Cited by
Analysis of focus measure operators for shape-from-focus
Pertuz, S., Puig, D., & Garcia, M. A. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.11.011 · Cited by 765
A no-reference objective image sharpness metric based on the notion of just noticeable blur (JNB)
Ferzli, R., & Karam, L. J. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2011760 · Cited by 758
Evaluation of autofocus functions in molecular cytogenetic analysis
SANTOS, A., ORTIZ DE SOLÓRZANO, C., VAQUERO, J. J., PEÑA, J. M., MALPICA, N., & DEL POZO, F. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.2630819.x · Cited by 375
Image Sharpness Assessment Based on Local Phase Coherence
Hassen, R., Wang, Z., & Salama, M. M. A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2251643 · Cited by 290
A global view of protein expression in human cells, tissues, and organs
Pontén, F., Gry, M., Fagerberg, L., Lundberg, E., Asplund, A., Berglund, L., Oksvold, P., Björling, E., Hober, S., Kampf, C., et al. (2009) · Molecular Systems Biology · doi:10.1038/msb.2009.93 · Cited by 222
Metadata
- Authors
- Firestone, L., Cook, K., Culp, K., Talsania, N., & Preston, K.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 12
- Issue
- 3
- Pages
- 195-206
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2067469524
- Cited by
- 348
- References
- 7
- FWCI
- 16.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of autofocus methods for automated microscopy. https://app.cochat.ai/papers/10.1002/cyto.990120302
- The paper
- Firestone, L., Cook, K., Culp, K., Talsania, N., & Preston, K. (1991). Comparison of autofocus methods for automated microscopy. Cytometry. https://doi.org/10.1002/cyto.990120302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.