Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Micromanipulation by “multiple” optical traps created by a single fast scanning trap integrated with the bilateral confocal scanning laser microscope

Open access
Visscher, K., Brakenhoff, G. J., Krol, J. J.·1993·Cytometry

Abstract

We have developed a novel micromanipulator consisting of multiple optical traps created by scanning one single beam trap along a variable number of positions. Among other things, this enables the orientation of irregularly shaped and relatively large structures which could not be oriented by just one trap as is demonstrated on long Escherichia coli bacteria filaments. We expect that the multiple trap manipulator will broaden the field of applications of optical trapping as a micromanipulation technique. For example, it facilitates the study of mechanical properties of extended structures as illustrated by a “bending”‐experiment using E. coli bacterium filaments. A special application of the multiple trap manipulator is the “indirect trapping” of objects which we did by keeping them held between other optically trapped particles. Indirect trapping makes it possible to trap particles which either cannot be trapped directly due to their optical properties (refractive index) or for which exposure to the laser radiation is undesirable. The multiple optical trap manipulator is controlled interactively by a UNIX workstation coupled to a VME instrumentation bus. This provides great flexibility in the control of the position and the orientation of the optical traps. Micromanipulation makes it desirable to have real time 3D microscopy for imaging and guidance of the optical traps. Therefore we integrated optical micromanipulation and a specially developed real‐time confocal microscope. This so called bilateral confocal scanning laser microscope (bilateral CSLM) [Brakenhoff and Visscher, J Microsc 165:139–146, 1992] produces images at video rate. © 1993 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.990140202

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 180

Metadata

Authors
Visscher, K., Brakenhoff, G. J., & Krol, J. J.
Venue
Cytometry
Publisher
Wiley
Published
1993-01
Volume
14
Issue
2
Pages
105-114
ISSN
  • 0196-4763 (ISSN-L)
  • 1097-0320
OpenAlex
W1983666980
Cited by
180
References
1
FWCI
1.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Micromanipulation by “multiple” optical traps created by a single fast scanning trap integrated with the bilateral confocal scanning laser microscope. https://app.cochat.ai/papers/10.1002/cyto.990140202
The paper
Visscher, K., Brakenhoff, G. J., & Krol, J. J. (1993). Micromanipulation by “multiple” optical traps created by a single fast scanning trap integrated with the bilateral confocal scanning laser microscope. Cytometry. https://doi.org/10.1002/cyto.990140202

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.