The DOI matches its Crossref record.
Sensitive method for measuring apoptosis and cell surface phenotype in human thymocytes by flow cytometry
Open accessAbstract
A rapid, gentle, and sensitive method for quantification of cells undergoing apoptosis is presented. The method allows the simultaneous determination of dual‐color cell surface immunofluorescence. Cells are stained for 7 min with the vital dye Hoechst 33342 (HO342) for identification of live and apoptotic cells. 7‐amino‐actinomycin D (7‐AAD) is added to distinguish cells that have lost membrane integrity from apoptotic and live cells. Due to its spectral properties 7‐AAD can be utilized on cells that are dual‐surface labelled with fluoresceinisothiocyanate (FITC) and phycoerythrin (PE). The value of the method is demonstrated on human thymocytes, which constitutively undergo programmed cell death and which show an increase in the rate of apoptosis after exposure to the glucocorticoid dexamethasone (DEX). Vital staining with HO342 permits earlier detection of apoptotic changes compared to a staining technique in which cells are treated with a hypotonic citrate solution containing propidium iodide (PI) and the apoptotic cells are represented in a hypodiploid, “sub‐G 1” peak. The HO342/7AAD method may be particularly applicable to studies of programmed cell death in cells in which DNA fragmentation is difficult to detect by decreased DNA stainability. © 1994 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Negative regulation of PKB/Akt-dependent cell survival by the tumor suppressor PTEN
Stambolic, V., Suzuki, A., de la Pompa, J. L., Brothers, G. M., Mirtsos, C., Sasaki, T., Ruland, J., Penninger, J. M., Siderovski, D. P., & Mak, T. W. (1998) · Cell · doi:10.1016/s0092-8674(00)81780-8 · Cited by 2,551
Yeh, W.-C., Itie, A., Elia, A. J., Ng, M., Shu, H.-B., Wakeham, A., Mirtsos, C., Suzuki, N., Bonnard, M., Goeddel, D. V., et al. (2000) · Immunity · doi:10.1016/s1074-7613(00)80214-9 · Cited by 515
Liu, Q., Sasaki, T., Kozieradzki, I., Wakeham, A., Itie, A., Dumont, D. J., & Penninger, J. M. (1999) · Genes & Development · doi:10.1101/gad.13.7.786 · Cited by 341
Schäfers, M., Lee, D. H., Brors, D., Yaksh, T. L., & Sorkin, L. S. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-07-03028.2003 · Cited by 270
Metadata
- Authors
- Schmid, I., Uittenbogaart, C. H., & Giorgi, J. V.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1994-01
- Volume
- 15
- Issue
- 1
- Pages
- 12-20
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W1992441650
- Cited by
- 221
- References
- 0
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive method for measuring apoptosis and cell surface phenotype in human thymocytes by flow cytometry. https://app.cochat.ai/papers/10.1002/cyto.990150104
- The paper
- Schmid, I., Uittenbogaart, C. H., & Giorgi, J. V. (1994). Sensitive method for measuring apoptosis and cell surface phenotype in human thymocytes by flow cytometry. Cytometry. https://doi.org/10.1002/cyto.990150104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.