The DOI matches its Crossref record.
Evaluation of methods for measuring cellular glutathione content using flow cytometry
Open accessAbstract
The currently available flow cytometric stains for cellular glutathione were evaluated, examining the labelling of both human and rodent cell lines under various conditions of concentration, time, and temperature. Procedures were used that depleted, glutathione (GSH) while having a minimal effect on other cellular sulphydryls in order to estimate linearity and the extent of background staining. As previously reported, monochlorobimane was highly specific for GSH in rodent cells but failed to label human cells adequately because of its low affinity for human glutathione S‐transferases. Higher concentrations of monochlorobimane achieved more complete labelling of, the human cellular GSH pool but gave increased background fluorescence due to non‐GSH binding. The analogue monobromobimane, which binds nonenzymatically to sulphydryls, reacted, more readily with GSH than with protein sulphydryls and, provided that stain concentration and incubation time were controlled, gave reproducible staining of human cells with 20% of total fluorescence due to background staining. Of the currently available stains for measuring GSH in human cells, monobromobimane is the agent of choice. Mercury orange also binds more readily to GSH than to protein, giving a degree of specificity, and it has the additional advantage of being excited at 488 nm. However, the reproducibility of staining with mercury orange was less consistent than that using monobromobimane, and a higher background fluorescence was seen. Two additional stains, O‐phthaldialdehyde and chloromethyl fluorescein, could also be used to label cellular GSH, but both gave an unacceptably high level of background staining. It is recommended that flow cytometric GSH assays should routinely include a sample of cells that have been depleted of GSH in order to determine the extent of background labelling. © 1994 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sandur, S. K., Pandey, M. K., Sung, B., Ahn, K. S., Murakami, A., Sethi, G., Limtrakul, P., Badmaev, V., & Aggarwal, B. B. (2007) · Carcinogenesis · doi:10.1093/carcin/bgm123 · Cited by 687
Glutathione deficiency is associated with impaired survival in HIV disease
Herzenberg, L. A., De Rosa, S. C., Dubs, J. G., Roederer, M., Anderson, M. T., Ela, S. W., Deresinski, S. C., & Herzenberg, L. A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.5.1967 · Cited by 670
Yoo, H. C., Park, S. J., Nam, M., Kang, J., Kim, K., Yeo, J. H., Kim, J.-K., Heo, Y., Lee, H. S., Lee, M. Y., et al. (2020) · Cell Metabolism · doi:10.1016/j.cmet.2019.11.020 · Cited by 449
Bernard, M., Jubeli, E., Pungente, M. D., & Yagoubi, N. (2018) · Biomaterials Science · doi:10.1039/c8bm00518d · Cited by 350
Sandur, S. K., Ichikawa, H., Pandey, M. K., Kunnumakkara, A. B., Sung, B., Sethi, G., & Aggarwal, B. B. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.05.009 · Cited by 331
Metadata
- Authors
- Hedley, D. W., & Chow, S.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1994-04
- Volume
- 15
- Issue
- 4
- Pages
- 349-358
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2062927875
- Cited by
- 245
- References
- 0
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of methods for measuring cellular glutathione content using flow cytometry. https://app.cochat.ai/papers/10.1002/cyto.990150411
- The paper
- Hedley, D. W., & Chow, S. (1994). Evaluation of methods for measuring cellular glutathione content using flow cytometry. Cytometry. https://doi.org/10.1002/cyto.990150411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.