Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record.

Tracking antigen‐driven responses by flow cytometry: Monitoring proliferation by dye dilution

Open access
Wallace, Paul K., Tario, Joseph D., Fisher, Jan L., Wallace, Stephen S., Ernstoff, Marc S., Muirhead, Katharine A. · 2008 · Cytometry Part A

Abstract

Cell‐tracking reagents such as the green‐fluorescent protein labeling dye CFSE and the red‐fluorescent lipophilic membrane dye PKH26 are commonly used to monitor cell proliferation by flow cytometry in heterogeneous cell populations responding to immune stimuli. Both reagents stain cells with a bright homogeneous fluorescence, which is partitioned between daughter cells during each cell division. Because daughter cell fluorescence intensities are approximately halved after each division, the intensity of a cell relative to its intensity at the time of staining provides information about how many divisions it has undergone. Knowing how many rounds of division have occurred and the relative number of cells in each daughter generation, one can back‐calculate the number of cells in the original population (i.e., cells present at the time of stimulus) that went on to respond by proliferating. Using this information, the precursor cell frequencies and extent of expansion to a specific antigen or mitogen of interest can be calculated. Concurrently, the phenotype of the cells can be determined, as well as their ability to bind antigen or synthesize cytokines, providing more detailed characterization of all cells responding to the antigen, not just effector cells. In multiparameter flow cytometric experiments to simultaneously analyze antigen‐specific tetramer binding, cytokine production and T‐cell proliferation, we found that only approximately half of the cells that exhibited specific binding to influenza tetramer also proliferated, as measured by dye dilution, and synthesized IFNγ in response to antigen. We expect the advent of new cell tracking dyes emitting from the violet to the near infrared combined with the increasing number of lasers and detectors on contemporary flow cytometers to further expand the usefulness of this approach to characterization of complex antigen‐driven immunological responses. © 2008 International Society for Advancement of Cytometry

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.20619

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Wallace, P. K., Tario, J. D., Fisher, J. L., Wallace, S. S., Ernstoff, M. S., & Muirhead, K. A.
Venue
Cytometry Part A
Publisher
Wiley
Published
2008-10-22
Volume
73A
Issue
11
Pages
1019-1034
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W1846756499
Cited by
159
References
0
FWCI
2.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tracking antigen‐driven responses by flow cytometry: Monitoring proliferation by dye dilution. https://app.cochat.ai/papers/10.1002/cyto.a.20619
The paper
Wallace, P. K., Tario, J. D., Fisher, J. L., Wallace, S. S., Ernstoff, M. S., & Muirhead, K. A. (2008). Tracking antigen‐driven responses by flow cytometry: Monitoring proliferation by dye dilution. Cytometry Part A. https://doi.org/10.1002/cyto.a.20619

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.