Update for the logicle data scale including operational code implementations
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Since its introduction in the early 2000s, the logicle data scale (1, 2) has been widely adopted by the cytometry community. The characteristics of logicle displays and their use to facilitate interpretation of flow cytometry data have been discussed in several papers (3, 4). FlowJo software (Tree Star, Ashland, OR) offers the option of setting logicle transformation as the default for some data types. Diva software (BD Biosciences, San Jose, CA) offers logicle displays with scaling customized to the distribution of the data in each plot (called "Biexponential" but using the logicle constraints on the biexponential and logicle methods for selecting display parameters). In our experience with data from many different biological applications and a variety of instruments, logicle transformation provides good representation of all cytometry data for which direct linear presentation is not the most appropriate choice and has shown no tendency to generate artifactual features in displays. On this basis, we now recommend logicle as the appropriate default method for nonlinear transformation of cytometric data. In support of this recommendation, this communication provides (1) minor updates to the logicle specification, (2) a rigorously defined parameterization that should clarify questions that have come from people who were implementing logicle transformations in software, (3) technical details that were not considered suitable for the original publication but have become important for the standardization and consistent application of the method, (4) reference implementation code for both high-precision and routine calculations, and (5) a more detailed mathematical exposition on Biexponential Functions (Supporting Information). We expect that the formulas presented here will be the normative definition for the logicle transformation included in the ISAC Standards Committee's recommendation in Gating-ML (Analytical Cytometry Standard (ACS)—Gating-ML Component, http://flowcyt.sourceforge.net/gating/). Implementations of the logicle scale in the Java, C++, and C programming languages are provided in the Supporting Information and are released under the Revised Berkeley Software Distribution open source license for free use in cytometry software. A module for integrating the logicle scale into the R statistical programming environment is available in the Bioconductor repository (http://www.bioconductor.org/). Several algorithms and computational methods used in this work were adopted or modified from Ref.5 (NR3, www.cambridge.org/numericalrecipes and www.nr.com). The objective in developing the logicle transform was to avoid the problems encountered with logarithmic scaling of cytometric data, when primary measurements and/or compensated data includes very low and negative values (illustrated in Fig. 1B). The inverse hyperbolic sine function (sinh−1) offers attractive features as a scaling function in that it gives a near-linear region above and below data zero, near-logarithmic behavior at high data values and a narrow but very smooth transition from one to the other. Transformations of this sort have been used for various kinds of data (6, 7). However, we found that sinh−1 and similar formulations do not provide enough flexibility to maintain consistent near-log behavior for high data values while adjusting the width and slope of the near-linear region to optimally display different data sets. Therefore, we adopted a more generalized biexponential form and constrained that so that a single width parameter (W in the mathematical expression below) sets the negative end of the scale and the width and slope of the near-linear region. This single parameter is used to tune the display for a particular data set. The only really comparable transform we are aware of is the HyperLog (8). Truncating a power series expansion of the negative exponential in a logicle formula to just the first-order term generates a HyperLog function. The full exponential function in the logicle version makes the near-linear region closer to linear and the near-log region closer to logarithmic compared to a corresponding HyperLog. Also, at least as originally formulated, HyperLog does not provide a single adjustable parameter comparable to the logicle width for matching to specific data sets. Appropriate and inappropriate selection of display types and display parameters. The lower histograms show events in the boxed region of the corresponding upper bivariate plots. In each of the logicle histograms, the left end of the integration bar approximates the median of the distribution. (A) Uncompensated logicle display of mouse spleen cells stained for only CD19 using a PE-Cy5.5 conjugated reagent and showing spectral overlap onto the PE-Cy7 channel. (B) A 4.5-decade logarithmic display of the same data compensated. The medians of both the CD19+ and the CD19− populations are near zero and below the minimum of the logarithmic scale. The apparent peak i
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpreting flow cytometry data: a guide for the perplexed
Herzenberg, L. A., Tung, J., Moore, W. A., Herzenberg, L. A., & Parks, D. R. (2006) · Nature Immunology · doi:10.1038/ni0706-681 · Cited by 464 · cited 3×
“The characteristics of logicle displays and their use to facilitate interpretation of flow cytometry data have been discussed in several papers (3,4).”
BackgroundMethodSelf-citation
Cited by
Bystander CD8+ T cells are abundant and phenotypically distinct in human tumour infiltrates
Simoni, Y., Becht, E., Fehlings, M., Loh, C. Y., Koo, S.-L., Teng, K. W. W., Yeong, J. P. S., Nahar, R., Zhang, T., Kared, H., et al. (2018) · Nature · doi:10.1038/s41586-018-0130-2 · Cited by 1,370
Critical assessment of automated flow cytometry data analysis techniques
The FlowCAP Consortium, Aghaeepour, N., The DREAM Consortium, Finak, G., Hoos, H., Mosmann, T. R., Brinkman, R., Gottardo, R., & Scheuermann, R. H. (2013) · Nature Methods · doi:10.1038/nmeth.2365 · Cited by 598
(2021) · doi:10.1016/j.celrep.2021.109507 · Cited by 21
(2025) · doi:10.1073/pnas.2514178122 · Cited by 2
Metadata
- Authors
- Moore, W. A., & Parks, D. R.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2012-03-12
- Volume
- 81A
- Issue
- 4
- Pages
- 273-277
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W2018119832
- Cited by
- 36
- References
- 1
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.