Platinum‐conjugated antibodies for application in mass cytometry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Mass cytometry has overcome limitations of fluorescent single cell cytometry by allowing for the measurement of up to currently ∼40 different parameters on a single cell level. However, the cellular proteome comprises many more potential analytes, and current mass cytometry instrumentation allows for theoretically up to 121 different mass detection channels. The labeling of specific probes with appropriate metal ions is a significant hurdle for exploiting more of mass cytometry's analytical capacity. To this end, we here describe the labeling of antibody with natural abundance or isotopically purified platinum as formulated in cisplatin and circumventing the use of chelator‐loaded polymers. We confirm the utility of cisplatin–antibody‐conjugates for surface, intracellular, and phosphoepitope‐specific immunophenotyping, as well as for application in cell surface CD45‐based barcoding. Cisplatin‐labeling of antibody increases the analytical capacity of the CyTOF® platform by two channels based on available reagents, and has the potential to add a total of six channels for detection of specific probes, thus helping to better extend the analytical mass range of mass cytometers. © 2015 International Society for Advancement of Cytometry
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Extracting a cellular hierarchy from high-dimensional cytometry data with SPADE
Qiu, P., Simonds, E. F., Bendall, S. C., Gibbs, K. D., Bruggner, R. V., Linderman, M. D., Sachs, K., Nolan, G. P., & Plevritis, S. K. (2011) · Nature Biotechnology · doi:10.1038/nbt.1991 · Cited by 956
Zunder, E. R., Finck, R., Behbehani, G. K., Amir, E.-A. D., Krishnaswamy, S., Gonzalez, V. D., Lorang, C. G., Bjornson, Z., Spitzer, M. H., Bodenmiller, B., et al. (2015) · Nature Protocols · doi:10.1038/nprot.2015.020 · Cited by 596
Newell, E. W., Sigal, N., Bendall, S. C., Nolan, G. P., & Davis, M. M. (2012) · Immunity · doi:10.1016/j.immuni.2012.01.002 · Cited by 555
Multiplexed mass cytometry profiling of cellular states perturbed by small-molecule regulators
Bodenmiller, B., Zunder, E. R., Finck, R., Chen, T. J., Savig, E. S., Bruggner, R. V., Simonds, E. F., Bendall, S. C., Sachs, K., Krutzik, P. O., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2317 · Cited by 546 · cited 1×
“4), a strategy that has been applied before to test barcoding methodologies (10).”
Background
Cited by
Severe COVID-19 Is Marked by a Dysregulated Myeloid Cell Compartment
Schulte-Schrepping, J., Reusch, N., Paclik, D., Baßler, K., Schlickeiser, S., Zhang, B., Krämer, B., Krammer, T., Brumhard, S., Bonaguro, L., et al. (2020) · Cell · doi:10.1016/j.cell.2020.08.001 · Cited by 1,461
Self-citationDistinct cellular mechanisms underlie anti-CTLA-4 and anti-PD-1 checkpoint blockade
Wei, S. C., Levine, J. H., Cogdill, A. P., Zhao, Y., Anang, N.-A. A. S., Andrews, M. C., Sharma, P., Wang, J., Wargo, J. A., Pe’er, D., et al. (2017) · Cell · doi:10.1016/j.cell.2017.07.024 · Cited by 1,302
NASH limits anti-tumour surveillance in immunotherapy-treated HCC
Pfister, D., Núñez, N. G., Pinyol, R., Govaere, O., Pinter, M., Szydlowska, M., Gupta, R., Qiu, M., Deczkowska, A., Weiner, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03362-0 · Cited by 1,294
Self-citationMass Cytometry: Single Cells, Many Features
Spitzer, M. H., & Nolan, G. P. (2016) · Cell · doi:10.1016/j.cell.2016.04.019 · Cited by 1,199
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citation
Metadata
- Authors
- Mei, H. E., Leipold, M. D., & Maecker, H. T.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2015-09-10
- Volume
- 89
- Issue
- 3
- Pages
- 292-300
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W2149895209
- Cited by
- 128
- References
- 5
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Platinum‐conjugated antibodies for application in mass cytometry. https://app.cochat.ai/papers/10.1002/cyto.a.22778
- The paper
- Mei, H. E., Leipold, M. D., & Maecker, H. T. (2016). Platinum‐conjugated antibodies for application in mass cytometry. Cytometry Part A. https://doi.org/10.1002/cyto.a.22778
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.