Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 84Advanced Fluorescence Microscopy TechniquesPhotochemistry and Electron Transfer Studiesbioluminescence and chemiluminescence research

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Overcoming limitations of FRET measurements

Open access
Leavesley, Silas J., Rich, Thomas C.·2016·Cytometry Part A

Abstract

FÖrster resonance energy transfer (FRET) is a non-radiative process that has been extensively applied for probing molecular events involved in a range of cellular and biological processes 1. FRET provides a means for measuring intermolecular spacings on the order ∼1–10 nm 2, an ability that has allowed measurement of cellular events such as protein folding, substrate interactions, enzyme kinetics, and intercellular signaling molecules. The advent of a wide range of fluorescent proteins from which to construct FRET reporters has enabled a variety of live-cell FRET studies to be readily conducted. In addition, newer techniques for gene manipulation have allowed generation of transgenic animal models expressing FRET reporters. The use of FRET-based reporters is now widespread, and in some cases FRET measurements have become the “gold-standard.” The potential for developing new genetic approaches allowing localized intracellular biochemical assays that make use of FRET measurements is high. Unfortunately, FRET approaches are associated with several limitations inherent in the physical process of FRET as well as the technologies used to measure FRET. For example, it is widely recognized that the fluorescence properties of many labels, especially fluorescent proteins, are sensitive to changes in local environment, such as changes in pH, ionic concentrations, oxidation, temperature, and refractive index. FRET measurements make use of two or more fluorescent labels, or proteins, each of which may present different sensitivities for changes in environmental factors. Hence, FRET measurements may be skewed by agonist-induced or unappreciated changes in local environment. Arguably the largest limitation of FRET measurements is the low signal-to-noise ratio (SNR) associated with FRET imaging. While many technologies have been developed to measure FRET, in general, all of them suffer from poor SNR when compared to imaging of a single fluorescent label. The governing factors behind the reduced SNR include the loss of energy associated with the FRET process and the fact that, whether directly or indirectly, two fluorescent molecules contribute to the measured FRET signal. These factors carry over into many different technologies that have been developed to measure FRET: filter set-based (traditional fluorescence microscopy), acceptor photobleaching, spectral FRET, and fluorescence lifetime imaging microscopy (FLIM) FRET. While we, and others, have shown that current state-of-the-art techniques such as spectral imaging and FLIM can reduce variance in FRET measurements 3, 4, these measurements still have low SNR when compared to imaging of a single label (Fig. 1). This low SNR, and the techniques of spectral and FLIM microscopy developed to overcome it, has often resulted in long exposure times (>1–2 sec) and uncertainty of the ability to differentiate between small differences in FRET efficiencies or interpret results based on small changes in FRET efficiency 7. Current state-of-the-art FRET measurement technologies suffer from reduced signal-to-noise ratios (SNR) when compared to measurement of a single fluorescent label or protein. A: Image of single-label acceptor emission using acceptor excitation (Venus, excited at 488 nm, expressed in pulmonary microvascular endothelial cells); (B) image of calculated FRET efficiency using hyperspectral confocal imaging shows reduced SNR when compared to the single-label image in Panel (A)—image shows a single expressing cell (Turquoise-Epac-Venus cAMP reporter5, excited at 405 nm, expressed in pulmonary microvascular endothelial cells); (C) image of fluorescence lifetime where greyscale intensity represents lifetime, masked to illustrate a single cell (Turqouoise-Epac-Venus cAMP reporter 5, expressed in HEK-293 cells); (D) the image from Panel (B), masked to remove nuclei, false-colored, and scaled to highlight changes in FRET efficiency; (E) the image from Panel (C), false-colored and scaled to highlight changes in fluorescence lifetime. Images (A, B, and D) were taken using identical objectives and acquisition parameters using a Nikon A1R spectral confocal microscope, with the exception of using a 488 nm laser for direct excitation of Venus in Panel (A). Images were then linearly unmixed using a non-negatively constrained unmixing algorithm implemented in MATLAB software, and converted to 8-bit and scaled linearly for display. Images (C, E) were provided by courtesy of Dr. Kees Jalink, van Leeuwenhoek Centre of Advanced Microscopy, Amsterdam, The Netherlands. SNR was calculated as described by Bernas and colleagues 6—in brief, pixels in regions of similar (but not oversaturated) intensity were identified using an 8-way high-pass filter and the mean intensity (signal) was calculated from the most homogeneous regions, while noise was calculated as the standard deviation of these regions and the SNR calculated as the ratio of mean intensity to standard deviation. [Color figure can be

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.22851

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 84

Metadata

Authors
Leavesley, S. J., & Rich, T. C.
Affiliations
University of South Alabama (US)
Corresponding author
Leavesley, Silas J.
Venue
Cytometry Part A
Publisher
Wiley
Published
2016-04
Volume
89
Issue
4
Pages
325-327
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W2341046904
Cited by
84
References
11
Citations by year
2026: 8 · 2025: 10 · 2024: 9 · 2023: 9 · 2022: 8 · 2021: 10 · 2020: 12 · 2019: 8 · 2018: 7 · 2017: 3
FWCI
3.77
Type
journal article
Language
en
Open access
Locations
  • Cytometry Part A (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health (P01 HL066299, S10 RR027535)
  • Cancer Aid and Research Fund
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Photochemistry and Electron Transfer Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
Keywords
fluorescence resonance energy transfer, signal-to-noise ratio, spectral imaging, fluorescence lifetime imaging, acceptor photobleaching, fluorescent proteins, FRET reporter, live-cell imaging
MeSH terms
Microscopy, Fluorescence, Fluorescence Resonance Energy Transfer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.