Elimination of erroneous results in flow cytometry caused by antibody binding to Fc receptors on human monocytes and macrophages
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Nonspecific binding of monoclonal antibodies (mAbs) to Fc‐receptors on leukocytes is an important cause of background fluorescence in flow cytometry, and failing to block such nonspecific binding can lead to erroneous results. A major part of previous studies on blocking reagents for flow cytometry have been done in mice, and published results are not completely in agreement. In humans, Fc‐receptors are found on most leukocytes, with highest abundance on monocytes/macrophages. Therefore, in the present study our aim was to thoroughly investigate the efficiency of different commonly used blocking reagents regarding inhibition of nonspecific binding of mouse mAbs to human peripheral blood mononuclear cells (MNCs) and monocyte‐derived macrophages (MDMs). Monocytes and MDMs showed strong nonspecific binding of IgG1 and IgG2a isotypes, but not IgG2b. In contrast, B‐cells, T‐cells, and NK‐cells did not substantially bind any of the mouse isotype control antibodies evaluated (IgG1, IgG2a, and IgG2b). Importantly, we show that binding of IgG1 and IgG2a to monocytes and MDMs can be eliminated by blocking, either with a commercial Fc‐blocking reagent, with mouse or human serum, or with mouse or human IgG in high concentration. Previously, isotype controls have been widely used in flow cytometry assays. However, we show that such controls may be highly unreliable, and we believe they should not be used as gating controls, or to determine background signal. Based on these results, as well as considerations of price and applicability, our recommendation is not to use isotypes as gating controls in flow cytometry, but instead to use 100 μg/mL of purified human IgG as blocking reagent for elimination of nonspecific binding of mouse mAbs to human MNCs and MDMs. © 2016 International Society for Advancement of Cytometry
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fcγ receptors as regulators of immune responses
Nimmerjahn, F., & Ravetch, J. V. (2008) · Nature Reviews Immunology · doi:10.1038/nri2206 · Cited by 2,947
Considerations for the control of background fluorescence in clinical flow cytometry
Hulspas, R., O'Gorman, M. R. G., Wood, B. L., Gratama, J. W., & Sutherland, D. R. (2009) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20485 · Cited by 255
Cited by
Normalizing and denoising protein expression data from droplet-based single cell profiling
Mulè, M. P., Martins, A. J., & Tsang, J. S. (2022) · Nature Communications · doi:10.1038/s41467-022-29356-8 · Cited by 197
Ovesen, P. L., Juul‐Madsen, K., Telugu, N. S., Schmidt, V., Frahm, S., Radbruch, H., Louth, E. L., Korshøj, A. R., Heppner, F. L., Diecke, S., et al. (2025) · Glia · doi:10.1002/glia.24659 · Cited by 14
Lucas, F., Gil‐Pulido, J., LaMacchia, J., Preffer, F., Wallace, P. K., & Lopez, P. (2020) · Cytometry Part A · doi:10.1002/cyto.a.23940 · Cited by 10
Metadata
- Authors
- Andersen, M. N., Al‐Karradi, S. N. H., Kragstrup, T. W., & Hokland, M.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2016-10-12
- Volume
- 89
- Issue
- 11
- Pages
- 1001-1009
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W2539131755
- Cited by
- 121
- References
- 2
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.