Fine‐needle aspiration cytology in lymphadenopathy of HIV‐positive patients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Fine‐needle aspiration cytology (FNAC) of 32 HIV‐positive cases presenting with lymphadenopathy was performed to evaluate its role in this group of patients. For each case air‐dried smears were stained with Leishman, hematoxylin and eosin, and Zeihl‐Neelsen stains for acid fast bacilli (AFB). The results were tuberculous (TB) lymphadenopathy (15), reactive lymphadenopathy (10), acute lymphadenitis/abscess (5), and suspected malignancy (2). In seven cases of TB lymphadenitis findings were suggestive of TB since no AFB was demonstrable on the cytology smears. In TB lymphadenitis, two additional patterns besides necrotising granulomatous (4) and granulomatous (2) were observed. These were necrotising (6) and necrotising suppurative (3) patterns. FNAC is a simple, inexpensive, rapid investigative procedure which can reduce surgical excisions and provide definite guidelines about further management. Diagn. Cytopathol. 2003;29:146–148. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficacy of fine needle aspiration cytology in the diagnosis of tuberculous cervical lymphadenopathy
Lau, S. K., Wei, W. I., Hsu, C., & Engzell, U. C. G. (1990) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100111697 · Cited by 176
Fine Needle Aspiration Diagnosis of Mycobacterial Lymphadenitis
Ellison, E., Lapuerta, P., & Martin, S. E. (1999) · Acta Cytologica · doi:10.1159/000330969 · Cited by 77
Cited by
Wright, C. A., van der Burg, M., Geiger, D., Noordzij, J. G., Burgess, S. M., & Marais, B. J. (2008) · Diagnostic Cytopathology · doi:10.1002/dc.20788 · Cited by 84
“Cytomorphology is simple, but not specific, as other opportunistic infections may present with similar cytological changes and the quality of the smear is operator dependent.(17,19) With good clinical triage of patients, its sensitivity and specificity can be increased.”
Background(2009) · PubMed · Cited by 52
Department of Medicine, P. A. D. R. H., Kumar, N., Gupta, B., Sharma, B., Kaushal, M., Rewari, B., & Sundriyal, D. (2014) · Hong Kong Medical Journal · doi:10.12809/hkmj144241 · Cited by 15
Cytomorphological Spectrums in Tuberculous Lymphadenitis: Understanding the Stages of Disease
Pradhan, A., Poudyal, P., Upadhyaya, P., & Pokhrel, S. (2018) · Journal of BP Koirala Institute of Health Sciences · doi:10.3126/jbpkihs.v1i2.22074 · Cited by 5
Metadata
- Authors
- Nayak, S., Mani, R., Kavatkar, A. N., Puranik, S. C., & Holla, V. V.
- Venue
- Diagnostic Cytopathology
- Publisher
- Wiley
- Published
- 2003-08-27
- Volume
- 29
- Issue
- 3
- Pages
- 146-148
- ISSN
- 1097-0339 (ISSN-L)
- 8755-1039
- OpenAlex
- W2029249657
- Cited by
- 39
- References
- 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.