The DOI matches its Crossref record.
Glucose monitoring by reverse iontophoresis
Abstract
Glucose can be extracted through intact skin by electro-osmotic flow (a process called 'reverse iontophoresis') upon the application of a low-level electrical current. Recently we have combined iontophoretic extraction with an in situ glucose sensor in a device called the GlucoWatch biographer. Clinical results with this device show close tracking of blood glucose over a range of 2.2 to 22.2 mmol/l for up to 12 h using a single blood glucose value as calibration. The biographer readings lag behind blood glucose values by an average of 18 min. An analysis of data from 92 diabetic subjects in a controlled clinical setting shows a linear relationship (r=0.88) between GlucoWatch biographer readings and blood glucose. The mean absolute relative difference between the two measurements was 15.6% and more than 96% of the data fell in the (A+B) regions of the Clarke error grid. Similar results have been obtained from subjects using the GlucoWatch biographer in an uncontrolled home environment. The automatic, frequent, and non-invasive measurements obtained with the GlucoWatch biographer provide substantially more information about glucose levels than do the current fingerstick methods. This information can be used for improved decisions about all aspects of diabetes management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Metadata
- Authors
- Potts, R. O., A. Tamada, J., & J. Tierney, M.
- Venue
- Diabetes/Metabolism Research and Reviews
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 18
- Issue
- S1
- Pages
- S49-S53
- ISSN
- 1520-7552 (ISSN-L)
- 1520-7560
- OpenAlex
- W1974433810
- Cited by
- 243
- References
- 0
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose monitoring by reverse iontophoresis. https://app.cochat.ai/papers/10.1002/dmrr.210
- The paper
- Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002). Glucose monitoring by reverse iontophoresis. Diabetes/Metabolism Research and Reviews. https://doi.org/10.1002/dmrr.210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.