Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Lung Ultrasound Integrated with Clinical Assessment for the Diagnosis of Acute Decompensated Heart Failure in the Emergency Department: A Randomized Controlled Trial

Open access
Pivetta, Emanuele, Goffi, Alberto, Nazerian, Peiman, Castagno, Davide, Tozzetti, Camilla, Tizzani, Pietro, Tizzani, Maria, Porrino, Giulio, Ferreri, Enrico, Busso, Valeria, Morello, Fulvio, Paglieri, Cristina, Masoero, Monica, Cassine, Elisa, Bovaro, Federica, Grifoni, Stefano, Maule, Milena M., Lupia, Enrico · 2019 · European Journal of Heart Failure

Abstract

Aims: Although acute decompensated heart failure (ADHF) is a common cause of dyspnoea, its diagnosis still represents a challenge. Lung ultrasound (LUS) is an emerging point-of-care diagnostic tool, but its diagnostic performance for ADHF has not been evaluated in randomized studies. We evaluated, in patients with acute dyspnoea, accuracy and clinical usefulness of combining LUS with clinical assessment compared to the use of chest radiography (CXR) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in conjunction with clinical evaluation. Methods and results: This was a randomized trial conducted in two emergency departments. After initial clinical evaluation, patients with acute dyspnoea were classified by the treating physician according to presumptive aetiology (ADHF or non-ADHF). Patients were subsequently randomized to continue with either LUS or CXR/NT-proBNP. A new diagnosis, integrating the results of both initial assessment and the newly obtained findings, was then recorded. Diagnostic accuracy and clinical usefulness of LUS and CXR/NT-proBNP approaches were calculated. A total of 518 patients were randomized. Addition of LUS had higher accuracy [area under the receiver operating characteristic curve (AUC) 0.95] than clinical evaluation alone (AUC 0.88) in identifying ADHF (P < 0.01). In contrast, use of CXR/NT-proBNP did not significantly increase the accuracy of clinical evaluation alone (AUC 0.87 and 0.85, respectively; P > 0.05). The diagnostic accuracy of the LUS-integrated approach was higher then that of the CXR/Nt-proBNP-integrated approach (AUC 0.95 vs. 0.87, p < 0.01). Combining LUS with the clinical evaluation reduced diagnostic errors by 7.98 cases/100 patients, as compared to 2.42 cases/100 patients in the CXR/Nt-proBNP group. Conclusion: Integration of LUS with clinical assessment for the diagnosis of ADHF in the emergency department seems to be more accurate than the current diagnostic approach based on CXR and NT-proBNP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ejhf.1379

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Pivetta, E., Goffi, A., Nazerian, P., Castagno, D., Tozzetti, C., Tizzani, P., Tizzani, M., Porrino, G., Ferreri, E., Busso, V., Morello, F., Paglieri, C., Masoero, M., Cassine, E., Bovaro, F., Grifoni, S., Maule, M. M., & Lupia, E.
Venue
European Journal of Heart Failure
Published
2019-01-28
Volume
21
Issue
6
Pages
754-766
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W2913730011
Cited by
227
References
5
FWCI
25.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.