Use of polymer films in amperometric biosensors

Emr, Sally A., Yacynych, Alexander M.·1995·Electroanalysis

Abstract

Different types of polymeric films implemented in various capacities in amperometric biosensor design are reviewed. Conducting and nonconductinzg polymer films and composite films are considered. Methods of film fabrication such as solvent casting, electropolymerization, and adsorption are presented. Film function, including prevention of interference and fouling problems, immobilization of the enzyme or active biocomponent, extension of linear range, or to address biocompatibility problems are described. The use of polymeric films as a medium to incorporate mediators, while an important function, is too vast for review here. The applications of polymer film‐modified biosensors for selected analytical determinations are also presented. This review focuses upon the use of polymer films in amperometric biosensors and emphasizes innovative biosensor designs and unique applications, and omits traditional free‐standing films unless they are coupled with new types of polymer films or used innovatively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.1140071002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Emr, S. A., & Yacynych, A. M.
Venue
Electroanalysis
Publisher
Wiley
Published
1995-10
Volume
7
Issue
10
Pages
913-923
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W2002490447
Cited by
202
References
0
FWCI
15.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of polymer films in amperometric biosensors. https://app.cochat.ai/papers/10.1002/elan.1140071002
The paper
Emr, S. A., & Yacynych, A. M. (1995). Use of polymer films in amperometric biosensors. Electroanalysis. https://doi.org/10.1002/elan.1140071002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.