Electrochecmical biosensors for DNA sequence detection
Abstract
A review of reported biosensors for the sequence‐selective detection of analyte DNA sequences shows that signal transduction based on electrogenerated chemiluminescence, potentiometry and voltammetry are all capable of detecting analyte DNA at attomole levels. In contrast, optical and piezoelectric transducers detect DNA at picomole and femtomole levels, respectively. The principles and applications of these promising electrochemical DNA biosensors are described and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Cutting out the middleman: DNA biosensors based on electrochemical oxidation
Thorp, H. H. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01162-1 · Cited by 255
Metadata
- Authors
- Mikkelsen, S. R.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 1996-01
- Volume
- 8
- Issue
- 1
- Pages
- 15-19
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2074429770
- Cited by
- 293
- References
- 0
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochecmical biosensors for DNA sequence detection. https://app.cochat.ai/papers/10.1002/elan.1140080104
- The paper
- Mikkelsen, S. R. (1996). Electrochecmical biosensors for DNA sequence detection. Electroanalysis. https://doi.org/10.1002/elan.1140080104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.