Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record.

A PVC‐based benzo‐15‐crown‐5 membrane sensor for cadmium

Srivastava, Suresh K., Gupta, Vinod K., Jain, Suresh·1996·Electroanalysis

Abstract

A plasticized poly (vinyl chloride) (PVC)‐based membrane of benzo‐l5‐crown‐5 exhibits a good response for Cd 2+ in a wide concentration range (3.16 × 10 5−1.00 × 10−1 M) with a slope of 20mV per decade of [Cd 2−]. The response time of the membrane sensor is < 30 s and the same can be used in a pH range 3.8 to 7.0. The electrode has been used, at one stretch, for a period of two months and displays good selectivity for Cd 2+ over alkali, alkaline earth and transition metal ions. The membrane sensor has also been used as an indicator electrode in potentiometric titration involving cadmium(II) ions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.1140081017

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 194

Metadata

Authors
Srivastava, S. K., Gupta, V. K., & Jain, S.
Venue
Electroanalysis
Publisher
Wiley
Published
1996-10
Volume
8
Issue
10
Pages
938-940
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W1965920822
Cited by
194
References
0
FWCI
2.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A PVC‐based benzo‐15‐crown‐5 membrane sensor for cadmium. https://app.cochat.ai/papers/10.1002/elan.1140081017
The paper
Srivastava, S. K., Gupta, V. K., & Jain, S. (1996). A PVC‐based benzo‐15‐crown‐5 membrane sensor for cadmium. Electroanalysis. https://doi.org/10.1002/elan.1140081017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.