Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors

Willner, Itamar, Katz, Eugenii, Willner, Bilha·1997·Electroanalysis

Abstract

Tailoring of electrically contacted enzyme electrodes provides the grounds for bioelectronic and biosensor systems. Redox‐enzymes organized onto electrodes as monolayer assemblies, and chemically functionalized by redox‐relay groups, yield electrically contacted enzyme electrodes exhibiting bioelectrocatalytic features. The sensitivity of the enzyme electrode can be enhanced, or tuned, by the organization of multilayer enzyme electrodes and the application of rough metal supports. Enzyme electrodes of extremely efficient electrical communication with the electrode are generated by the reconstitution of apo‐flavoenzymes onto relay‐FAD monolayers associated with electrodes. The reconstitution process results in an aligned enzyme on the surface, and its effective electrical contact with the electrode yields selective enzyme electrodes of unprecedented high current responses. Integrated electrodes consisting of relay‐NAD(P)+‐cofactor and enzyme units are generated by the reconstitution of NAD(P)+‐dependent enzymes onto a relay‐NAD(P)+ monolayer assembly followed by lateral crosslinking of the enzyme network.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.1140091302

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Willner, I., Katz, E., & Willner, B.
Venue
Electroanalysis
Publisher
Wiley
Published
1997-09
Volume
9
Issue
13
Pages
965-977
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W2067854686
Cited by
188
References
0
FWCI
22.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors. https://app.cochat.ai/papers/10.1002/elan.1140091302
The paper
Willner, I., Katz, E., & Willner, B. (1997). Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors. Electroanalysis. https://doi.org/10.1002/elan.1140091302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.