Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors
Abstract
Tailoring of electrically contacted enzyme electrodes provides the grounds for bioelectronic and biosensor systems. Redox‐enzymes organized onto electrodes as monolayer assemblies, and chemically functionalized by redox‐relay groups, yield electrically contacted enzyme electrodes exhibiting bioelectrocatalytic features. The sensitivity of the enzyme electrode can be enhanced, or tuned, by the organization of multilayer enzyme electrodes and the application of rough metal supports. Enzyme electrodes of extremely efficient electrical communication with the electrode are generated by the reconstitution of apo‐flavoenzymes onto relay‐FAD monolayers associated with electrodes. The reconstitution process results in an aligned enzyme on the surface, and its effective electrical contact with the electrode yields selective enzyme electrodes of unprecedented high current responses. Integrated electrodes consisting of relay‐NAD(P)+‐cofactor and enzyme units are generated by the reconstitution of NAD(P)+‐dependent enzymes onto a relay‐NAD(P)+ monolayer assembly followed by lateral crosslinking of the enzyme network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Metadata
- Authors
- Willner, I., Katz, E., & Willner, B.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 9
- Issue
- 13
- Pages
- 965-977
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2067854686
- Cited by
- 188
- References
- 0
- FWCI
- 22.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors. https://app.cochat.ai/papers/10.1002/elan.1140091302
- The paper
- Willner, I., Katz, E., & Willner, B. (1997). Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors. Electroanalysis. https://doi.org/10.1002/elan.1140091302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.