Electroconductive Hydrogels: Electrical and Electrochemical Properties of Polypyrrole‐Poly(HEMA) Composites
The DOI matches its Crossref record.
Abstract
Composites of inherently conductive polypyrrole (PPy) within highly hydrophilic poly(2‐hydroxyethyl methacrylate)‐based hydrogels (p(HEMA)) have been fabricated and their electrochemical properties investigated. The electrochemical characteristics observed by cyclic voltammetry suggest less facile reduction of PPy within the composite hydrogel compared to electropolymerized PPy, as shown by the shift in the reduction peak potential from −472 mV for electropolymerized polypyrrole to −636 mV for the electroconductive composite gel. The network impedance magnitude for the electroconductive hydrogel remains quite low, ca. 100 Ω, even upon approach to DC, over all frequencies and at all offset potentials suggesting retained electronic (bipolaronic) conductivity within the composite. In contrast, sustained application of +0.7 V (vs. Ag/AgCl, 3 M Cl−) for typically 100 min. (conditioning) to reduce the background amperometric current to <1.0 μA, resulted in complete loss of electroactivity. Nyquist plots suggest that sustained application of such a modest potential to the composite hydrogel results in impedance characteristics that resembles p(HEMA) without evidence of the conducting polymer component. PPy composite gels supported a larger ferrocene monocarboxylate diffusivity (Dappt=7.97×10−5 cm 2 s−1) compared to electropolymerized PPy (Dappt=5.56×10−5 cm 2 s−1), however a marked reduction in diffusivity (Dappt=1.01×10−5 cm 2 s−1) was observed with the conditioned hydrogel composite. Cyclic voltammograms in buffer containing H 2 O 2 showed an absence of redox peaks for electrodes coated with PPy‐containing membranes, suggesting possible chemical oxidation of polypyrrole by the oxidant
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646
Self-citationApplications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 429
Electrically conductive hydrogels for flexible energy storage systems
Zhang, W., Feng, P., Chen, J., Sun, Z., & Zhao, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.09.001 · Cited by 409
Graphene oxide/conducting polymer composite hydrogels
Bai, H., Sheng, K., Zhang, P., Li, C., & Shi, G. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm13918e · Cited by 307
Conducting polymer-hydrogels for medical electrode applications
Green, R. A., Baek, S., Poole-Warren, L. A., & Martens, P. J. (2010) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/11/1/014107 · Cited by 268
Tissue adhesive hydrogel bioelectronics
Li, S., Cong, Y., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb00523e · Cited by 257
Carboxylic Acid-Functionalized Conductive Polypyrrole as a Bioactive Platform for Cell Adhesion
Lee, J.-W., Serna, F., Nickels, J., & Schmidt, C. E. (2006) · Biomacromolecules · doi:10.1021/bm060220q · Cited by 227
Electrochemical polymerization of conducting polymers in living neural tissue
Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l02 · Cited by 195
Assays for aptamer-based platforms
Citartan, M., Gopinath, S. C. B., Tominaga, J., Tan, S.-C., & Tang, T.-H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.01.002 · Cited by 188
Li, L., Meng, J., Zhang, M., Liu, T., & Zhang, C. (2022) · Chemical Communications · doi:10.1039/d1cc05526g · Cited by 175
Degradable and Electroactive Hydrogels with Tunable Electrical Conductivity and Swelling Behavior
Guo, B., Finne-Wistrand, A., & Albertsson, A.-C. (2011) · Chemistry of Materials · doi:10.1021/cm103498s · Cited by 164
Electrically Conductive, Tough Hydrogels with pH Sensitivity
Naficy, S., Razal, J. M., Spinks, G. M., Wallace, G. G., & Whitten, P. G. (2012) · Chemistry of Materials · doi:10.1021/cm301666w · Cited by 162
He, J., Zhang, A., Zhang, Y., & Guan, Y. (2011) · Macromolecules · doi:10.1021/ma1029532 · Cited by 48
Metadata
- Authors
- Brahim, S., & Guiseppi‐Elie, A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-04
- Volume
- 17
- Issue
- 7
- Pages
- 556-570
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2072482998
- Cited by
- 85
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.