The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Disposable Biosensor for Organophosphorus Nerve Agents Based on Carbon Nanotubes Modified Thick Film Strip Electrode
Abstract
A disposable biosensor based on acetylcholinesterase‐functionalized acid purified multi‐wall carbon nanotubes (CNTs) modified thick film strip electrode for organophosphorus (OP) insecticides was developed. The degree of inhibition of the enzyme acteylcholinesterase (AChE) by OP compounds was determined by measuring the electrooxidation current of the thiocholine generated by the AChE catalyzed hydrolysis of acteylthiocholine (ATCh). The large surface area and electro‐catalytic activity of carbon nanotubes lowered the overpotential for thiocholine oxidation to 200 mV (vs. Ag/AgCl) without the use of mediating redox species and enzyme immobilization by physical adsorption. The biosensor detected as low as 0.5 nM (0.145 ppb) of the model organophosphate nerve agent paraoxon with good precision, electrode to electrode reproducibility and stability. Analysis of real water sample using the sensor demonstrated the feasibility of the application of the sensor for on site monitoring of OP compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Cited by
Mohamad, N. R., Marzuki, N. H. C., Buang, N. A., Huyop, F., & Wahab, R. A. (2015) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2015.1008192 · Cited by 1,440
Perspectives for nano-biotechnology enabled protection and nutrition of plants
Ghormade, V., Deshpande, M. V., & Paknikar, K. M. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.007 · Cited by 1,184
Destruction and Detection of Chemical Warfare Agents
Kim, K., Tsay, O. G., Atwood, D. A., & Churchill, D. G. (2011) · Chemical Reviews · doi:10.1021/cr100193y · Cited by 1,011
New materials for electrochemical sensing VI: Carbon nanotubes
Merkoçi, A., Pumera, M., Llopis, X., Pérez, B., del Valle, M., & Alegret, S. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.03.019 · Cited by 685
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
Metadata
- Authors
- Joshi, K. A., Tang, J., Haddon, R., Wang, J., Chen, W., & Mulchandani, A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 17
- Issue
- 1
- Pages
- 54-58
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2064693070
- Cited by
- 230
- References
- 1
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.