The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
CuO Nanospheres Based Nonenzymatic Glucose Sensor
Abstract
CuO nanospheres, synthesized by a simple one‐step hydrothermal method, have been applied to modify the glassy carbon (GC) electrode for sensitive nonenzymatic glucose detection. The CuO nanospheres modified electrode, compared to the Nafion modified GC electrode, exhibits an enhanced electrocatalytic property for direct glucose oxidation and shows a fast response and a high sensitivity for the amperometric detection of glucose. It has been determined that the dissolved oxygen is not involved in glucose oxidation and the high concentration of NaCl does not poison the electrode. These results also indicate that CuO nanospheres have great potential application in electrochemical detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Zinc oxide nanocomb biosensor for glucose detection
Wang, J. X., Sun, X. W., Wei, A., Lei, Y., Cai, X. P., Li, C. M., & Dong, Z. L. (2006) · Applied Physics Letters · doi:10.1063/1.2210078 · Cited by 595
Self-citationNonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Li, Y., Song, Y.-Y., Yang, C., & Xia, X.-H. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.11.035 · Cited by 515
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W. (2006) · Applied Physics Letters · doi:10.1063/1.2356307 · Cited by 442
Self-citationHighly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes
Ye, J.-S., Wen, Y., De Zhang, W., Ming Gan, L., Xu, G. Q., & Sheu, F.-S. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.10.013 · Cited by 325
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Karikalan, N., Karthik, R., Chen, S.-M., Karuppiah, C., & Elangovan, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-02479-5 · Cited by 319
Liang, X., Zhang, S., Meng, S., Tan, R., Zhang, K., & Hu, J. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111690 · Cited by 24
Metadata
- Authors
- Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2008-11
- Volume
- 20
- Issue
- 22
- Pages
- 2482-2486
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2147284301
- Cited by
- 346
- References
- 28
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CuO Nanospheres Based Nonenzymatic Glucose Sensor. https://app.cochat.ai/papers/10.1002/elan.200804327
- The paper
- Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y. (2008). CuO Nanospheres Based Nonenzymatic Glucose Sensor. Electroanalysis. https://doi.org/10.1002/elan.200804327
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.