The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Improved silver staining procedure for fast staining in PhastSystem Development Unit. I. Staining of sodium dodecyl sulfate gels
Abstract
A new modification of silver staining of proteins in sodium dodecyl sulfate polyacrylamide gels is adapted to automated staining in PhastSystem Development Unit. The use of a reduction step, after fixation, with thiosulfate in alcoholic sodium acetate buffer results in a considerable increase in sensitivity without the need for a recycling step. The detection limit is tenfold lower than in the silver staining procedure recommended so far for PhastSystem and corresponds to 0.05–0.1 ng protein per band. Total staining time with the new procedure is 75 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morrissey, J. H. (1981) · Analytical Biochemistry · doi:10.1016/0003-2697(81)90783-1 · Cited by 4,061
Heukeshoven, J., & Dernick, R. (1985) · ELECTROPHORESIS · doi:10.1002/elps.1150060302 · Cited by 1,335
Self-citationSimplified silver protein detection and image enhancement methods in polyacrylamide gels
Merril, C. R., Goldman, D., & Van Keuren, M. L. (1982) · ELECTROPHORESIS · doi:10.1002/elps.1150030104 · Cited by 379
A simplification of Heukeshoven and Dernick's silver staining of proteins
Damerval, C., Guilloux, M. L., Blaisonneau, J., & de Vienne, D. (1987) · ELECTROPHORESIS · doi:10.1002/elps.1150080308 · Cited by 163
Artifacts in sodium dodecyl sulfate-polyacrylamide gel electrophoresis due to 2-mercaptoethanol
Tasheva, B., & Dessev, G. (1983) · Analytical Biochemistry · doi:10.1016/0003-2697(83)90057-x · Cited by 160
Cited by
The current state of two-dimensional electrophoresis with immobilized pH gradients
Görg, A., Obermaier, C., Boguth, G., Harder, A., Scheibe, B., Wildgruber, R., & Weiss, W. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1037::aid-elps1037>3.0.co;2-v · Cited by 1,515
Zabel, U., & Baeuerle, P. A. (1990) · Cell · doi:10.1016/0092-8674(90)90806-p · Cited by 430
Interaction of DNA polymerase alpha-primase with cellular replication protein A and SV40 T antigen.
Dornreiter, I., Erdile, L. F., Gilbert, I. U., von Winkler, D., Kelly, T. J., & Fanning, E. (1992) · The EMBO Journal · doi:10.1002/j.1460-2075.1992.tb05110.x · Cited by 368
Sauer, N., & Stolz, J. (1994) · The Plant Journal · doi:10.1046/j.1365-313x.1994.6010067.x · Cited by 366
Zabel, U., Schreck, R., & Baeuerle, P. A. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)52428-5 · Cited by 344
Metadata
- Authors
- Heukeshoven, J., & Dernick, R.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1988-01
- Volume
- 9
- Issue
- 1
- Pages
- 28-32
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W1974956422
- Cited by
- 693
- References
- 5
- FWCI
- 12.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.