The DOI matches its Crossref record.
Essential problems in quantification of proteins following colloidal staining with Coomassie Brilliant Blue dyes in polyacrylamide gels, and their solution
Abstract
Quantitative determination of stained proteins following polyacrylamide gel electrophoresis (PAGE) is of increasing interest especially since computer‐aided densitometers have become available as well as recipes for sensitive and background‐free staining with Coomassie Brilliant Blue dyes. However, avoidance of separation artifacts is not the only essential prerequisite for quantitative evaluation. The local particle density of a protein in a given gel is of critical importance since it determines its stainability. Depending on local protein concentration, the dye binding to the same amount of a given protein differs considerably. Since the stainability of proteins using colloidal staining procedures, as with Coomassie Brilliant Blue dyes, is time‐dependent and, in addition, also dependent on the pore size of a given polyacrylamide gel used for PAGE, calibration curves for quantitative determinations have to be prepared in polyacrylamide gels of the same composition as used for PAGE. Staining conditions also have to be identical for calibration gels and gels under analysis. If, however, a set of calibration curves is prepared for different staining times, it is possible to calculate a generalized calibration curve, allowing for quantitative evaluation with flexible staining time. Furthermore, and in consequence of the implications due to particle density, quantitative determination via densitometry is only possible by determining the protein amount of each single measuring point (pixel) via its absorbance on the basis of a calibration curve. Since the particle density is inherent in a calibration curve, the final summation of the protein amount per pixel will give values close to reality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomic Approach to Identify Novel Mitochondrial Proteins in Arabidopsis
Kruft, V., Eubel, H., Jänsch, L., Werhahn, W., & Braun, H.-P. (2001) · Plant Physiology · doi:10.1104/pp.010474 · Cited by 371
Gene clusters involved in anaerobic benzoate degradation of Geobacter metallireducens
Wischgoll, S., Heintz, D., Peters, F., Erxleben, A., Sarnighausen, E., Reski, R., Van Dorsselaer, A., & Boll, M. (2005) · Molecular Microbiology · doi:10.1111/j.1365-2958.2005.04909.x · Cited by 153
Metalloprotease Meprin β Generates Nontoxic N-terminal Amyloid Precursor Protein Fragments in Vivo
Jefferson, T., Čaušević, M., auf dem Keller, U., Schilling, O., Isbert, S., Geyer, R., Maier, W., Tschickardt, S., Jumpertz, T., Weggen, S., et al. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.252718 · Cited by 108
Metadata
- Authors
- Neuhoff, V., Stamm, R., Pardowitz, I., Arold, N., Ehrhardt, W., & Taube, D.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1990-01
- Volume
- 11
- Issue
- 2
- Pages
- 101-117
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2080311659
- Cited by
- 220
- References
- 0
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Essential problems in quantification of proteins following colloidal staining with Coomassie Brilliant Blue dyes in polyacrylamide gels, and their solution. https://app.cochat.ai/papers/10.1002/elps.1150110202
- The paper
- Neuhoff, V., Stamm, R., Pardowitz, I., Arold, N., Ehrhardt, W., & Taube, D. (1990). Essential problems in quantification of proteins following colloidal staining with Coomassie Brilliant Blue dyes in polyacrylamide gels, and their solution. ELECTROPHORESIS. https://doi.org/10.1002/elps.1150110202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.