Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 512

The DOI matches its Crossref record.

Autoradiography using storage phosphor technology

Johnston, Richard F., Pickett, Siobhan C., Barker, David L.·1990·ELECTROPHORESIS

Abstract

We describe the application of photostimulable storage phosphor imaging plates to autoradiography of samples labeled with 32 P, 14 C and 35 S. Imaging plates can detect a 32 P‐labeled sample at an exposure level of 1 disintegration/mm 2, and 14 C and 35 S at 25 disintegrations/mm 2. Compared to X‐ray film, imaging plates offer increased sensitivity of 15‐ to 250‐fold for 32 P and 20‐ to 100‐fold for 14 C and 35 S. Resolution is in the 0.3 mm range and is therefore suitable for any gel or blot application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.1150110503

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 512

Metadata

Authors
Johnston, R. F., Pickett, S. C., & Barker, D. L.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
1990-01
Volume
11
Issue
5
Pages
355-360
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W1965694122
Cited by
512
References
0
FWCI
59.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Autoradiography using storage phosphor technology. https://app.cochat.ai/papers/10.1002/elps.1150110503
The paper
Johnston, R. F., Pickett, S. C., & Barker, D. L. (1990). Autoradiography using storage phosphor technology. ELECTROPHORESIS. https://doi.org/10.1002/elps.1150110503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.