The DOI matches its Crossref record.
Trace analysis of proteins by capillary zone electrophoresis with on‐column transient isotachophoretic preconcentration
Abstract
The qualitative and quantitative aspects of transient isotachophoretic (ITP) sample preconcentration in the capillary zone electrophoretic analysis of protein samples have been demonstrated. By the proper selection of components of the background electrolyte and/or additives to the sample solution, two basic electrolyte arrangements have been employed. In the first, a typical isotachophoretic electrolyte system consisting of a leading and terminating electrolyte was used, and after focusing and preconcentration, the terminating electrolyte was replaced by the leading electrolyte, with the separation being continued in the zone electrophoretic mode. In the second, only one background electrolyte was used, containing a co‐ion with low electrophoretic mobility, and the sample was supplemented with a salt of a highly mobile co‐ion. In this case transient isotachophoretic migration of the sample ions took place at the beginning of the migration and gradually changed to the zone electrophoretic mode. Sample mixtures containing basic (positively charged) or acidic (negatively charged) proteins were examined using surface‐coated fused‐silica capillaries. For acidic proteins, bare silica was also tested. The isotachophoretic sample stacking permitted injection and preconcentration of sample volumes two to three orders of magnitude higher than usual in capillary zone electrophoresis. For example, up to 1 μL was injected into a 75 μm ID capillary. This approach afforded quantitative analysis of protein samples in the concentration range of 10−7–10−8 M, with detection limits of approximately 10−9 M. Furthermore, with constant sample volume injected, good reproducibility of migration times was obtained. Finally, the determination of trace components in the presence of a major sample component using transient ITP preconcentration has been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, J., Xu, J., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001126h · Cited by 257
Tong, W., Link, A., Eng, J. K., & Yates, J. R. (1999) · Analytical Chemistry · doi:10.1021/ac9901182 · Cited by 143
Zhang, Z., Albanetti, T., Linkous, T., Larkin, C. J., Schoner, R., McGivney, J. B., & Dovichi, N. J. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600390 · Cited by 23
Metadata
- Authors
- Foret, F., Szökő, E., & Karger, B. L.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 14
- Issue
- 1
- Pages
- 417-428
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2057813853
- Cited by
- 173
- References
- 0
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trace analysis of proteins by capillary zone electrophoresis with on‐column transient isotachophoretic preconcentration. https://app.cochat.ai/papers/10.1002/elps.1150140167
- The paper
- Foret, F., Szökő, E., & Karger, B. L. (1993). Trace analysis of proteins by capillary zone electrophoresis with on‐column transient isotachophoretic preconcentration. ELECTROPHORESIS. https://doi.org/10.1002/elps.1150140167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.