The DOI matches its Crossref record.
Protein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing
Open accessAbstract
A new protein fractionation technique based on off‐gel isoelectric focusing (IEF) is presented, where the proteins are separated according to their isoelectric point (p I) in a multiwell device with the advantage to be directly recovered in solution for further analysis. The protein fractions obtained with this technique have then been characterized with polymer nanoelectrospray for mass spectrometry (MS) analyses or with Bioanalyzer for mass identification. This methodology shows the possibility of developing alternatives to the classical two‐dimensional (2‐D) gel electrophoresis. One species numerical simulation of the electric field distribution during off‐gel separation is also presented in order to demonstrate the principle of the purification. Experiments with p I protein markers have been carried out in order to highlight the kinetics and the efficiency of the technique. Moreover, the resolution of the fractionation was shown to be 0.1 pH unit for the separation of β‐lactoglobulin A and B. In addition, the isoelectric fractionation of an Escherichia coli extract was performed in standard solubilization buffer to demonstrate the performances of the technique, notably for proteomics applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Keshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700354-mcp200 · Cited by 684
Proteomics: Challenges, Techniques and Possibilities to Overcome Biological Sample Complexity
Chandramouli, K., & Qian, P.-Y. (2009) · Human Genomics and Proteomics · doi:10.4061/2009/239204 · Cited by 511
Terminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
Prefractionation techniques in proteome analysis: The mining tools of the third millennium
Righetti, P. G., Castagna, A., Antonioli, P., & Boschetti, E. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200406189 · Cited by 281
Metadata
- Authors
- Michel, P. E., Reymond, F., Arnaud, I. L., Josserand, J., Girault, H. H., & Rossier, J. S.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 24
- Issue
- 1-2
- Pages
- 3-11
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W1990137485
- Cited by
- 165
- References
- 0
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing. https://app.cochat.ai/papers/10.1002/elps.200390030
- The paper
- Michel, P. E., Reymond, F., Arnaud, I. L., Josserand, J., Girault, H. H., & Rossier, J. S. (2003). Protein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing. ELECTROPHORESIS. https://doi.org/10.1002/elps.200390030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.