A comparison of the consistency of proteome quantitation using two‐dimensional electrophoresis and shotgun isobaric tagging in Escherichia coli cells
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An important consideration in the measurement of quantitative changes in protein expression is the consistency of the observations for a given technique as well as the reproducibility of the experiment. A quantitative assessment of the technical and biological variability is crucial to avoid erroneous inferences and conclusions. Two methods for measuring quantitative changes in protein expression are two‐dimensional electrophoresis (2‐DE) and shotgun proteomics of isobaric‐tagged samples using iTRAQ™ reagents. An assessment of changes in Escherichia coli protein expression in response to rhsA induction demonstrates that half of the quantified protein expression ratios have a coefficent of variation (CV) less than 0.31 using 2‐DE and less than 0.24 using isobaric tags; whereas 95% of the quantified protein expression ratios have a CV less than 0.81 using 2‐DE and less than 0.53 using isobaric tags. The selective removal of outlier data points from the shotgun method using Grubb's and Rosner's statistical outlier tests improves the consistency of the quantitation data obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Cited by
Wu, W. W., Wang, G., Baek, S. J., & Shen, R.-F. (2006) · Journal of Proteome Research · doi:10.1021/pr050405o · Cited by 576
Addressing Accuracy and Precision Issues in iTRAQ Quantitation
Karp, N. A., Huber, W., Sadowski, P. G., Charles, P. D., Hester, S. V., & Lilley, K. S. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900628-mcp200 · Cited by 495
Shotgun proteomics using the iTRAQ isobaric tags
Aggarwal, K. (2006) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/ell018 · Cited by 345
Self-citationProteomics in gram‐negative bacterial outer membrane vesicles
Lee, E., Choi, D., Kim, K., & Gho, Y. S. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20175 · Cited by 339
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
Metadata
- Authors
- Choe, L. H., Aggarwal, K., Franck, Z., & Lee, K. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2005-06
- Volume
- 26
- Issue
- 12
- Pages
- 2437-2449
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W1978702876
- Cited by
- 106
- References
- 2
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.