Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

High‐abundance protein depletion: Comparison of methods for human plasma biomarker discovery

Open access
Polaskova, Veronika, Kapur, Amit, Khan, Alamgir, Molloy, Mark P., Baker, Mark S. · 2010 · ELECTROPHORESIS

Abstract

Affinity depletion of abundant proteins from human plasma has become a routine sample preparation strategy in proteomics used prior to protein identification and quantitation. To date, there have been limited published studies comparing the performance of commercially available depletion products. We conducted a thorough evaluation of six depletion columns using 2‐DE combined with sophisticated image analysis software, examining the following criteria: (i) efficiency of high‐abundance protein depletion, (ii) non‐specific removal of other than the targeted proteins and (iii) total number of protein spots detected on the gels following depletion. From all the products investigated, the Seppro IgY system provided the best results. It displayed the greatest number of protein spots on the depleted plasma gels, minimal non‐specific binding and high efficiency of abundant protein removal. Nevertheless, the increase in the number of detected spots compared with the second best performing and cheaper multiple affinity removal column (MARC) was not shown to be statistically significant. The ProteoPrep spin column, considered to be the “deepest” depletion technique available at the time of conducting the study, surprisingly displayed significantly fewer spots on the flow‐through fraction gels compared with both the Seppro and the MARC. The spin column format and low plasma capacity were also found to be impractical for 2‐DE. To conclude, we succeeded in providing an overview of the depletion columns performances with regard to the three examined areas. Our study will serve as a reference to other scientists when deciding on the optimal product for their particular projects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200900286

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 174

Metadata

Authors
Polaskova, V., Kapur, A., Khan, A., Molloy, M. P., & Baker, M. S.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2010-01
Volume
31
Issue
3
Pages
471-482
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W1974213285
Cited by
174
References
3
FWCI
7.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐abundance protein depletion: Comparison of methods for human plasma biomarker discovery. https://app.cochat.ai/papers/10.1002/elps.200900286
The paper
Polaskova, V., Kapur, A., Khan, A., Molloy, M. P., & Baker, M. S. (2010). High‐abundance protein depletion: Comparison of methods for human plasma biomarker discovery. ELECTROPHORESIS. https://doi.org/10.1002/elps.200900286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.