Dispersive liquid–liquid microextraction coupled with capillary electrophoresis for simultaneous determination of sulfonamides with the aid of experimental design
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A novel method for the simultaneous determination of sulfonamides (SAs) in water samples has been developed by using dispersive liquid–liquid microextraction (DLLME) coupled with CE. Orthogonal and Box–Behnken designs were employed together to assist the optimization of DLLME parameters, including volumes of extraction and disperser solvents, ionic strength, extraction time, and centrifugation time and speed as variable factors. Under the optimum extraction and detection conditions, successful separation of the five SAs was achieved within 5 min, and excellent analytical performances were attained, such as good linear relationships (R>0.980) between peak area and concentration for each SA from 0.5 to 50 μg/mL, low limits of detection for the five SAs between 0.020 and 0.570 μg/mL and the intra‐day precisions of migration time below 0.80%. The method recoveries obtained at fortified 10 μg/mL for three water samples ranged from 53.6 to 94.0% with precisions of 1.23–5.60%. The proposed method proved highly sensitive and selective, rapid, convenient and cost‐effective, showing great potential for the simultaneous determination of SAs in water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Dispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 294
Wu, Q., Wang, C., Liu, Z., Wu, C., Zeng, X., Wen, J., & Wang, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.062 · Cited by 174
Wu, Q., Li, Y., Wang, C., Liu, Z., Zang, X., Zhou, X., & Wang, Z. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.02.017 · Cited by 168
Cited by
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Niu, Z., Zhang, W., Yu, C., Zhang, J., & Wen, Y. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.02.005 · Cited by 188
Self-citationTen years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Ji, Y., Meng, Z., Zhao, J., Zhao, H., & Zhao, L. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460520 · Cited by 89
Zahiri, E., Khandaghi, J., Farajzadeh, M. A., & Afshar Mogaddam, M. R. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461390 · Cited by 86
Li, G., Wang, W., Wang, Q., & Zhu, T. (2015) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmv138 · Cited by 54
Metadata
- Authors
- Wen, Y., Li, J., Zhang, W., & Chen, L.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2011-07-27
- Volume
- 32
- Issue
- 16
- Pages
- 2131-2138
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2169406067
- Cited by
- 88
- References
- 6
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.