Toward a screening method for the analysis of small intact proteins by CE‐ESI‐TOF MS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Capillary electrophoresis‐mass spectrometry (CE‐MS) more and more gains in importance as an analytical technique for the identification and characterization of intact proteins in the biopharmaceutical area. Thus, a CE‐ESI‐MS method was optimized and validated systematically with respect to the improved screening and characterization of intact proteins. The optimization was accomplished by variation of different CE‐MS parameters, such as capillary coating, background electrolyte, sheath liquid, and nebulizer gas pressure, while monitoring both the resolution and signal intensities. Achievable separation is discussed quantitatively in the context of the coating and the resulting EOF, the protein mobilities, and the suction effect of the sprayer. The observed precisions of the optimized method regarding the migration times (mean RSD = 1.4%) and peak areas (mean RSD = 12.3%) and an extensive principal component analysis revealed that the presented method is reliable and useful for the quantitation of intact proteins and protein isoforms. The applicability of this method to various proteins showing different characteristics (p I value, molecular mass, hydrophobicity, etc.) is discussed. The presented method will contribute to the improved characterization of a large variety of intact proteins in the biomedical and pharmaceutical area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Cited by
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
CE‐MS for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96
Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Jayo, R. G., Thaysen-Andersen, M., Lindenburg, P. W., Haselberg, R., Hankemeier, T., Ramautar, R., & Chen, D. D. Y. (2014) · Analytical Chemistry · doi:10.1021/ac5010212 · Cited by 54
Sánchez‐Hernández, L., Montealegre, C., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600464 · Cited by 29
Self-citation
Metadata
- Authors
- Taichrib, A., Pioch, M., & Neusüß, C.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2012-05
- Volume
- 33
- Issue
- 9-10
- Pages
- 1356-1366
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W1595974409
- Cited by
- 43
- References
- 1
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.