Size distribution analysis of residual host cell DNA fragments in lentivirus by CGE-LIF
Abstract
During the production of cell and gene therapy products, residual host cell DNA (HCD) could cause safety risks of the biological products, and the longer the residual HCD fragment, the greater the risk to the human body. For this reason, it was necessary to develop an effective method for the size distribution analysis of residual HCD fragments with high accuracy and sensitivity. In this study, capillary gel electrophoresis with laser-induced fluorescence detector (CGE-LIF) was used to analyze the size distribution of residual HCD fragments in lentivirus products. The results confirmed that lentiviral RNA genome could interfere with the size distribution analysis of residual HCD fragments. By optimizing the amount of RNase I and digestion time in sample pretreatment process, the interfere of RNA genome could be avoided. The specificity, precision, accuracy, linear range, the detection of limit (LOD), and the quantification of limit (LOQ) of CGE-LIF method were also validated. The results showed that the CGE-LIF method had a good performance both in terms of specificity and reproducibility. The intra- and inter-day relative standard deviations of migration time and corrected peak area were all less than 1% and 2%, respectively. The 200 bp DNA marker had a good linearity between 50 and 1000 pg/ml. The LOD and LOQ of 200 bp DNA marker were 2.59 and 8.64 pg/ml, respectively. In addition, this method was successfully used to analyze the size distribution analysis of residual HCD f…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There have been reports on the analysis of particle size distribution of residual HCD fragments in lentiviral products from different processes.
“There have been reports on the analysis of particle size distribution of residual HCD fragments in lentiviral products from different processes [33].”
From Evaluation of the Efficacy of the Vaccine Production Process in Removing Residual Host Cell DNA from the Vero Cell Rabies Vaccine (2024) · cites this paper as [33]
Cites
High, K. A., & Roncarolo, M. G. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1706910 · Cited by 555 · see citing works
Lentiviral Vectors in Gene Therapy: Their Current Status and Future Potential
Escors, D., & Breckpot, K. (2010) · Archivum Immunologiae et Therapiae Experimentalis · doi:10.1007/s00005-010-0063-4 · Cited by 344 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Li, J., Pan, R., Yue, F., Gao, T., Wu, X., Shi, L., Wang, Y., Zhao, D., Lan, Z., Chen, H., et al. (2024) · Vaccines · doi:10.3390/vaccines12121379 · Cited by 8 · see citing works
Self-citation
- Authors
- Wang, W., Gao, T., Luo, J., Guo, L., Li, X., Li, Y., & Chen, H.
- Affiliations
- SCIEX Beijing P. R. China
- National Institutes for Food and Drug Control (CN)
- National Medical Products Administration (CN)
- Corresponding author
- Li, Xiang
- Li, Yan
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2022-11-21
- Volume
- 44
- Issue
- 3-4
- Pages
- 462-471
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W4308679411
- Cited by
- 7
- References
- 2
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Electrophoresis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Virus-based gene therapy research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- lentivirus, cell and gene therapy products, product safety, method validation
- MeSH terms
- DNA, Genetic Markers, Humans, Reproducibility of Results, Lentivirus, Polymerase Chain Reaction, Electrophoresis, Capillary
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review