CoChat

Two‐Photon polymerization for microfabrication of three‐dimensional scaffolds for tissue engineering application

Weiß, Thomas, Hildebrand, Gerhard, Schade, Ronald, Liefeith, Klaus · 2009 · Engineering in Life Sciences

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

In natural tissues cells are embedded in a three‐dimensional fibrous network of biopolymers like collagen, hyaluronic acid etc. This extracellular matrix (ECM) influences the cell fate, the differentiation status, metabolic processes and provides structural integrity. For a three‐dimensional or physiological cell cultivation that are required in biomedical applications (e.g. tissue engineering, BioMEMS) scaffolds are needed. These scaffolds mimic the ECM according to their biocompatibility which comprises aspects of surface compatibility and importantly for tissue engineering applications aspects of structural compatibility. We have evaluated scaffold design parameters for the three‐dimensional cultivation of chondrocytes for the tissue engineering of artificial cartilage. Two‐photon polymerization is a powerful technique for fabrication of polymeric three‐dimensional micro‐ and submicro‐structures. The photoinitiation system for two‐photon polymerization is excited by simultaneous absorption of two photons leading to chemical polymerization reactions. Due to a tight confinement of the excitation volume around the focal point, this method can produce micrometer sized objects maintaining a high spatial resolution down to 100 nm. Two‐photon processes require very high photon densities which are provided by pulsed femtosecond lasers. The potential of this approach for microfabrication of scaffolds for tissue engineering is demonstrated by investigation of the cell response to microstructures with complex three‐dimensional geometry and feature sizes in the range of few micrometers.

Overview

Integrity signals

Registry

Crossref · 10.1002/elsc.200900002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 36 · Cited by 121

Metadata

Authors
Weiß, T., Hildebrand, G., Schade, R., & Liefeith, K.
Affiliations
  • Institute for Bioprocessing and Analytical Measurement Techniques (DE)
  • Innovent (DE)
Venue
Engineering in Life Sciences
Publisher
Wiley
Published
2009-10
Volume
9
Issue
5
Pages
384-390
ISSN
  • 1618-0240 (ISSN-L)
  • 1618-2863
OpenAlex
W2134326799
Cited by
121
References
36
Citations by year
2026: 1 · 2025: 6 · 2024: 5 · 2023: 14 · 2022: 6 · 2021: 8 · 2020: 6 · 2019: 8 · 2018: 15 · 2017: 5 · 2016: 4 · 2015: 4 · 2014: 7 · 2013: 7 · 2012: 9
FWCI
5.01
Type
journal article
Language
en
Open access
closed
Locations
Engineering in Life Sciences (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nonlinear Optical Materials Studies
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
two-photon polymerization, 3D scaffolds, tissue engineering, chondrocytes, cartilage tissue engineering, extracellular matrix mimicry, microfabrication, femtosecond laser, BioMEMS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two‐Photon polymerization for microfabrication of three‐dimensional scaffolds for tissue engineering application. https://app.cochat.ai/papers/10.1002/elsc.200900002
The paper
Weiß, T., Hildebrand, G., Schade, R., & Liefeith, K. (2009). Two‐Photon polymerization for microfabrication of three‐dimensional scaffolds for tissue engineering application. Engineering in Life Sciences. https://doi.org/10.1002/elsc.200900002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.