The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Passive daytime radiative cooling: Fundamentals, material designs, and applications
Open accessAbstract
Passive daytime radiative cooling (PDRC) dissipates terrestrial heat to the extremely cold outer space without using any energy input or producing pollution. It has the potential to simultaneously alleviate the two major problems of energy crisis and global warming. In this review, we summarize general strategies implemented for achieving PDRC and various applications of PDRC technologies. We first introduce heat transfer processes involved in PDRC, including radiative and nonradiative heat transfer processes, to evaluate the PDRC performance. Subsequently, we summarize the general material designs used for controlling PDRC performance, such as tuning the thermal mid‐infrared emittance and solar reflectance. Finally, we discuss the diverse applications of PDRC technologies to overcome problems in space cooling, solar cell cooling, water harvesting, and electricity generation. image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Progress in Daytime Radiative Cooling: Is It the Air Conditioner of the Future?
Santamouris, M., & Feng, J. (2018) · Buildings · doi:10.3390/buildings8120168 · Cited by 167
Comprehensive evaluation of thermal and energy performance of radiative roof cooling in buildings
Chen, J., & Lu, L. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101631 · Cited by 93
Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China
Guo, R., Gao, Y., Zhuang, C., Heiselberg, P., Levinson, R., Zhao, X., & Shi, D. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.10.032 · Cited by 58
Cited by
Radiative cooling for passive thermal management towards sustainable carbon neutrality
Liang, J., Wu, J., Guo, J., Li, H., Zhou, X., Liang, S., Qiu, C.-W., & Tao, G. (2023) · National Science Review · doi:10.1093/nsr/nwac208 · Cited by 281
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
High-Performance Transparent Radiative Cooler Designed by Quantum Computing
Kim, S., Shang, W., Moon, S., Pastega, T., Lee, E., & Luo, T. (2022) · ACS Energy Letters · doi:10.1021/acsenergylett.2c01969 · Cited by 119
Metadata
- Authors
- Chen, M., Pang, D., Chen, X., Yan, H., & Yang, Y.
- Venue
- EcoMat
- Publisher
- Wiley
- Published
- 2021-10-30
- Volume
- 4
- Issue
- 1
- ISSN
- 2567-3173 (ISSN-L)
- OpenAlex
- W3209504157
- Cited by
- 203
- References
- 3
- FWCI
- 13.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Passive daytime radiative cooling: Fundamentals, material designs, and applications. https://app.cochat.ai/papers/10.1002/eom2.12153
- The paper
- Chen, M., Pang, D., Chen, X., Yan, H., & Yang, Y. (2022). Passive daytime radiative cooling: Fundamentals, material designs, and applications. EcoMat. https://doi.org/10.1002/eom2.12153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.