Cited by 45Vibration Control and Rheological FluidsSeismic Performance and AnalysisSeismic and Structural Analysis of Tall Buildings

The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.

Damping systems that are effective over a wide range of displacement amplitudes using metallic yielding component and viscoelastic damper in series

Yamamoto, Masashi, Sone, Takayuki·2014·Earthquake Engineering & Structural Dynamics

Abstract

SUMMARY A damper system that absorbs energy over a wide range of displacement amplitudes during building vibration was proposed. This system uses a serial connection of a metallic yielding component and viscoelastic damper with a displacement limit mechanism. Three types of the system were developed and tested: a diagonal bracing type, inverted V bracing type, and wall type. The test results showed that all these systems have damping ratios higher than 8% at small vibration amplitudes on the order of 0.1 mm. For a large vibration, a displacement limit mechanism with two pins limited the displacement of the viscoelastic damper as designed. Analytical simulations established that the system reduced the acceleration and the story drift to 60–70% and 80%, respectively, during a small earthquake compared with a conventional metallic yielding damper system. Furthermore, it showed an equivalent control performance during a severe earthquake. The damper system requires that a clearance be maintained for the displacement limit mechanism. However, this may be lost through construction error, residual displacement after an earthquake, and temperature effects. The changes in the clearance due to these effects were discussed. Copyright © 2014 John Wiley & Sons, Ltd.

Overview

Integrity signals

Registry

Crossref · 10.1002/eqe.2438

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 14

  1. TsaiCS ChenKC ChenCS.Seismic resistibility of high‐rise buildings with combined velocity‐dependent and velocity‐independent devices.ASME Pressure Vessels and Piping Conference San Diego CA1998;366:103–110.
  2. Watanabe A, 1999, Experimental study of steel dampers in combination with visco‐elastic material, Summaries of Technical Papers of Annual Meeting AIJ, 2, 1021
  3. Ikahata N, 1999, Design of building with seismic control system by Maxwell‐type hybrid viscous elasto‐plastic damper, Summaries of Technical Papers of Annual Meeting AIJ, 2, 1025
  4. Kimura Y, 2003, Development of hybrid energy dissipation system combined elasto‐plastic damper and visco‐elastic damper: Part 4 and 5, Summaries of Technical Papers of Annual Meeting AIJ, 2, 829
  5. CharneyFA IbrahimYE.New visco‐plastic passive energy device.Proc. of 13th World Conference on Earthquake Engineering Vancouver Canada 2004; No. 118.
  6. Kimura Y, 2006, Development of energy dissipation column system combined elasto‐plastic damper and visco‐elastic damper: part 1, 2, Summaries of Technical Papers of Annual Meeting AIJ, 2, 815
  7. YamamotoM HigashinoM SoneT. A damping system that is effective in a broad range of displacement using steel damper and viscoelastic damper in series.Proc. of International Symposium on Network and Center-Based Research for Smart Structures Technologies and Earthquake Engineering Osaka Japan 2004;591–596.
  8. Yamamoto M, 2004, Development of a damping system with connecting visco‐elastic damper and steel damper in series that is effective in a wide range of vibration amplitude: part 1: general view and results of dynamic loading tests. Part 2: analytical studies based on the theme structure, Summaries of Technical Papers of Annual Meeting AIJ, 2, 167
  9. Sone T, 2007, Development of a damping system with connecting visco‐elastic damper and steel damper in series that is effective in a wide range of vibration amplitude: part 4: microtremor measurements and free vibration tests, Summaries of Technical Papers of Annual Meeting AIJ, 2, 845
  10. Sone T, 2008, Development of a damping system with connecting visco‐elastic damper and steel damper in series that is effective in a wide range of vibration amplitude: part 5: results of loading tests of K‐braced system, Summaries of Technical Papers of Annual Meeting AIJ, 2, 541
  11. Sone T, 2012, Experimental studies of a wall typed damping system that is effective in a broad range of displacement using steel damper and viscoelastic damper in series, Journal of Structural Engineering AIJ, 58, 217
  12. Ishikawa K, 2003, Development of a visco‐elastic damper for a building isolation system that constrains its displacement: part 2: performance test of new visco‐elastic material using scale down test piece, Summaries of Technical Papers of Annual Meeting AIJ, 2, 579
  13. DoiM IchiokaY OhtaY KonoS WatanabeF.Seismic behavior of hybrid system with corrugated steel shear panel and RC frame.Proc. of 14th World Conference on Earthquake Engineering Beijing China 2008; No. 12‐01‐0122.
  14. OhbuchiT MoriH YoshieK HaraH ArimaF TakeuchiY SaitouY IshiM KasaiK.Proposed theme structure and analytical modeling study for passive control system.Proc. of 2002 Passive Control Symposium2002;195–204(in Japanese).

Cited by

Sorted by citations

Metadata

Authors
Yamamoto, M., & Sone, T.
Affiliations
Takenaka (Japan) (JP)
Corresponding author
Yamamoto, Masashi
Venue
Earthquake Engineering & Structural Dynamics
Publisher
Wiley
Published
2014-05-14
Volume
43
Issue
14
Pages
2097-2114
ISSN
  • 0098-8847 (ISSN-L)
  • 1096-9845
OpenAlex
W2115054685
Cited by
45
References
17
Citations by year
2026: 3 · 2025: 8 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 2
FWCI
4.47
Type
journal article
Language
en
Open access
closed
Locations
Earthquake Engineering & Structural Dynamics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
  • Physical Sciences › Engineering › Civil and Structural Engineering › Seismic Performance and Analysis
  • Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
Keywords
damping devices, viscoelastic dampers, building vibration, seismic response reduction, inter-story drift, damping ratio, diagonal bracing, inverted V bracing, residual displacement, temperature effects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review