A new passive rolling‐pendulum vibration absorber using a non‐axial‐symmetrical guide to achieve bidirectional tuning
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A new, passive, vibroprotective device of the rolling‐pendulum tuned mass damper type is presented that, relying on a proper three‐dimensional guiding surface, can simultaneously control the response of the supporting structure in two mutually orthogonal horizontal directions. Unlike existing examples of ball vibration absorbers, mounted on spherical recesses and effective for axial‐symmetrical structures, the new device is bidirectionally tuneable, by virtue of the optimum shape of the rolling cavity, to both fundamental structural modes, even when the corresponding natural frequencies are different, in such a case recurring to an innovative non‐axial‐symmetrical rolling guide. Based on Appell's non‐holonomic mechanics, a non‐linear dynamic model is first derived for the bidirectional absorber mounted on a 1‐storey 3‐degrees‐of‐freedom linear structure translating under the effect of both imparted base motion and applied dynamic forces. A laboratory‐scaled prototype of the device is then tested to experimentally demonstrate the bidirectional tuning capability and to validate the mathematical model. The design procedure and the seismic performance of the absorber are finally exemplified through numerical simulation. Copyright © 2009 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651
Optimal tuned mass damper for seismic applications and practical design formulas
Hoang, N., Fujino, Y., & Warnitchai, P. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2007.05.007 · Cited by 382
Dynamic characteristics of multiple substructures with closely spaced frequencies
Xu, K., & Igusa, T. (1992) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290211203 · Cited by 326
Design formulas for tuned mass dampers based on a perturbation technique
Fujino, Y., & Abé, M. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221002 · Cited by 276
Performance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Inelastic buildings with tuned mass dampers under moderate ground motions from distant earthquakes
Lukkunaprasit, P., & Wanitkorkul, A. (2001) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.22 · Cited by 64
Cited by
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
On a nonlinear single-mass two-frequency pendulum tuned mass damper to reduce horizontal vibration
Viet, L. D., & Nghi, N. B. (2014) · Engineering Structures · doi:10.1016/j.engstruct.2014.09.038 · Cited by 49
Li, C. (2012) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.624 · Cited by 35
Metadata
- Authors
- Matta, E., De Stefano, A., & Spencer, B. F.
- Venue
- Earthquake Engineering & Structural Dynamics
- Publisher
- Wiley
- Published
- 2009-06-08
- Volume
- 38
- Issue
- 15
- Pages
- 1729-1750
- ISSN
- 0098-8847 (ISSN-L)
- 1096-9845
- OpenAlex
- W2004943415
- Cited by
- 47
- References
- 6
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.