The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Exergy analysis of a 420 MW combined cycle power plant
Open accessAbstract
Combined cycle power plants (CCPPs) have an important role in power generation. The objective of this paper is to evaluate irreversibility of each part of Neka CCPP using the exergy analysis. The results show that the combustion chamber, gas turbine, duct burner and heat recovery steam generator (HRSG) are the main sources of irreversibility representing more than 83% of the overall exergy losses. The results show that the greatest exergy loss in the gas turbine occurs in the combustion chamber due to its high irreversibility. As the second major exergy loss is in HRSG, the optimization of HRSG has an important role in reducing the exergy loss of total combined cycle. In this case, LP-SH has the worst heat transfer process. The first law efficiency and the exergy efficiency of CCPP are calculated. Thermal and exergy efficiencies of Neka CCPP are 47 and 45.5% without duct burner, respectively. The results show that if the duct burner is added to HRSG, these efficiencies are reduced to 46 and 44%. Nevertheless, the results show that the CCPP output power increases by 7.38% when the duct burner is used. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Exergy Method of Thermal Plant Analysis
(1985) · Elsevier eBooks · doi:10.1016/c2013-0-00894-8 · Cited by 2,895
Fundamentals of Engineering Thermodynamics
Moran, M. J., & Shapiro, H. N. (1988) · Cited by 2,442
Fundamentals of Engineering Thermodynamics
Babu, V. (2019) · CRC Press eBooks · doi:10.1201/9780367816087 · Cited by 1,599
International Journal of Energy Research
Kilicarslan, A., & Uller, N. M. (2006) · International Journal of Energy Research · doi:10.1002/(issn)1099-114x · Cited by 707
Availability analysis: A guide to efficient energy use
Moran, M. (1982) · Cited by 688
The role of exergy in energy policy making
Dincer, I. (2002) · Energy Policy · doi:10.1016/s0301-4215(01)00079-9 · Cited by 482
Cited by
Ahmadi, P., Dincer, I., & Rosen, M. A. (2011) · Energy · doi:10.1016/j.energy.2011.08.034 · Cited by 546
Self-citationA novel hybrid agent-based model predictive control for advanced building energy systems
Sangi, R., & Müller, D. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.08.111 · Cited by 40
Metadata
- Authors
- Ameri, M., Ahmadi, P., & Khanmohammadi, S.
- Venue
- International Journal of Energy Research
- Publisher
- Hindawi Limited
- Published
- 2008
- Volume
- 32
- Issue
- 2
- Pages
- 175-183
- ISSN
- 0363-907X (ISSN-L)
- 1099-114X
- OpenAlex
- W2059533431
- Cited by
- 268
- References
- 6
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exergy analysis of a 420 MW combined cycle power plant. https://app.cochat.ai/papers/10.1002/er.1351
- The paper
- Ameri, M., Ahmadi, P., & Khanmohammadi, S. (2008). Exergy analysis of a 420 MW combined cycle power plant. International Journal of Energy Research. https://doi.org/10.1002/er.1351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.