The DOI matches its Crossref record.
Review on bipolar plates for low‐temperature polymer electrolyte membrane water electrolyzer
Open accessAbstract
Electrolysis coupled with renewable energy resources is the most promising method for green hydrogen production. Polymer electrolyte membrane water electrolyzer (PEMWE) has attracted attention due to its ability to produce high-purity, compressed hydrogen at relatively mild operating temperatures (70°C-90°C). The highest cost contributor of the PEMWE stack are the bipolar plates (BPPs). Owing to the severe operating conditions (acidity from the membrane and high localized oxygen concentration) of the PEMWE stack, appropriate material and fabrication are crucial to ensure high performance and durability. The role of BPPs in mass transport and electrical charge transfer must be further understood and correlated to its specific application in PEMWE. At the most basic level, BPPs must have low interfacial contact resistance and high corrosion resistance to withstand the conditions within the stack. The most common base materials for BPP construction include austenitic stainless steel (SS316 and SS403) and Ti due to their flexural strength and ease of mass production. A coating layer is also necessary to protect the substrate from corrosion, and the most popular materials include TiN and other noble metals with nonpassivated oxides and reliable electrical conductivity. The compromise between material robustness and cost is currently a delicate balance toachieve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anion-exchange membrane water electrolyzers and fuel cells
Yang, Y., Li, P., Zheng, X., Sun, W., Dou, S. X., Ma, T., & Pan, H. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00038e · Cited by 575
Stability of electrocatalytic OER: from principle to application
Li, H., Lin, Y., Duan, J., Wen, Q., Liu, Y., & Zhai, T. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00010a · Cited by 540
Salehmin, M. N. I., Husaini, T., Goh, J., & Sulong, A. B. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115985 · Cited by 329
Self-citationAdvances in Oxygen Evolution Electrocatalysts for Proton Exchange Membrane Water Electrolyzers
Chen, Z., Guo, L., Pan, L., Yan, T., He, Z., Li, Y., Shi, C., Huang, Z., Zhang, X., & Zou, J. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202103670 · Cited by 298
Metadata
- Authors
- Teuku, H., Alshami, I., Goh, J., Masdar, M. S., & Loh, K. S.
- Venue
- International Journal of Energy Research
- Publisher
- Wiley
- Published
- 2021-08-16
- Volume
- 45
- Issue
- 15
- Pages
- 20583-20600
- ISSN
- 0363-907X (ISSN-L)
- 1099-114X
- OpenAlex
- W3195256156
- Cited by
- 174
- References
- 0
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review on bipolar plates for low‐temperature polymer electrolyte membrane water electrolyzer. https://app.cochat.ai/papers/10.1002/er.7182
- The paper
- Teuku, H., Alshami, I., Goh, J., Masdar, M. S., & Loh, K. S. (2021). Review on bipolar plates for low‐temperature polymer electrolyte membrane water electrolyzer. International Journal of Energy Research. https://doi.org/10.1002/er.7182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.